2008
DOI: 10.1016/j.sab.2008.03.015
|View full text |Cite
|
Sign up to set email alerts
|

Plasma diagnostic on a low-flow plasma for inductively coupled plasma optical emission spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
22
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(23 citation statements)
references
References 48 publications
0
22
1
Order By: Relevance
“…It should be noted, that calculated here the ionization temperature and the electron number density were significantly lower than those reported for Fig. 10 The electron number density and ionization temperature for the liquid cathode-solid anode system an atmospheric pressure ICP source [27,34]. It is mainly connected with the power of the applied plasma source and conditions of the plasma generation.…”
Section: The Excitation Vibrational and Rotational Temperatures In Tcontrasting
confidence: 52%
See 2 more Smart Citations
“…It should be noted, that calculated here the ionization temperature and the electron number density were significantly lower than those reported for Fig. 10 The electron number density and ionization temperature for the liquid cathode-solid anode system an atmospheric pressure ICP source [27,34]. It is mainly connected with the power of the applied plasma source and conditions of the plasma generation.…”
Section: The Excitation Vibrational and Rotational Temperatures In Tcontrasting
confidence: 52%
“…The electron number density and ionization degree of Mg changed over the range (3.4 -6.8) 9 10 20 m -3 and 9-21%, respectively. For comparison, in an atmospheric pressure ICP the electron density is one to two orders higher, the Mg ionization degree reaches 95-99% while the excitation and ionization temperatures are usually between 5,000 and 10,000 K [34], so the APGD plasma is much more far from the LTE state than the ICP. However, the results indicate that deviations from local thermal equilibrium are not large and rather depend on plasma generation conditions.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…5a. This particular selection of OH lines was used in many other studies [24][25][26][27]. The measurements were carried out for the same positions as relative OH intensity measurements (Fig.…”
Section: Temperature Profile From Oesmentioning
confidence: 99%
“…Though these low gas flow torches could sustain ICPs under low Ar plasma gas flow rate, lower RF forward power was applied compared with the ICP sustained by the Fassel type torch (from 1.3 to 1.5 kW), in order to prevent torch melting. A SHIP (static high sensitivity ICP) torch which was one of the air cooled torches for ICPOES was reported; [17][18][19][20][21] however, the torch could also input lower RF forward power of up to 1.2 kW.…”
Section: Introductionmentioning
confidence: 99%