2014
DOI: 10.1080/14399776.2014.893712
|View full text |Cite
|
Sign up to set email alerts
|

Pilot operated miniature valve with fast response and high flow capacity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 1 publication
0
9
0
Order By: Relevance
“…In order to make digital valve systems a feasible alternative for proportional valves in a wider area of applications, their size must be reduced. Research into miniaturizing digital valve systems has been conducted for close to ten years now and it is ongoing [4][5][6] . Miniaturizing the individual on/off valves reduces the dimensions of the valve systems or enables including a larger number of valves in a certain sized valve system, thus improving the control resolution of flow rate and the motion of hydraulic actuators.…”
Section: Introductionmentioning
confidence: 99%
“…In order to make digital valve systems a feasible alternative for proportional valves in a wider area of applications, their size must be reduced. Research into miniaturizing digital valve systems has been conducted for close to ten years now and it is ongoing [4][5][6] . Miniaturizing the individual on/off valves reduces the dimensions of the valve systems or enables including a larger number of valves in a certain sized valve system, thus improving the control resolution of flow rate and the motion of hydraulic actuators.…”
Section: Introductionmentioning
confidence: 99%
“…Lantela et al [45] perhaps most closely answered Scheidl et alś call for a standardised on/off valve that could be cascaded and combined to meet the needs of the larger digital fluid power community. By developing a valve requiring only 4cm 3 of volume whilst still flowing 9L/min at a 35bar pressure drop and having multiple instances machined onto a block, the dream of a single valve design that can be utilised through the field is closer.…”
Section: Digital Valvesmentioning
confidence: 96%
“…Nonetheless it is worthwhile to compare the performance of the valve with other proposed designs. Lantela et al [45] provide in their recent paper a comparison of their valve, other digital hydraulic prototypes and two commercially available valves. Table 7.1 appends the performance of the valve in this paper to the list and adds a new metric, rate of change of flow, which looks at how much flow each valve is able to switch.…”
Section: Valvementioning
confidence: 99%
“…, when the pilot valve controlled by the pulse width modulation, the control pressure above the poppet alternate between the supply pressure and the tank pressure while the pressure under the poppet is always equal to the supply pressure. Driven by the control pressure and the supply pressure, the poppet can connect or disconnect the hydraulic [35]. A 3/2 spool valve is applied as the pilot stage and a 2/2 ball valve is used as the main stage.…”
Section: Direct Drive Hsvmentioning
confidence: 99%
“…Due to the high power density of the hydraulic transmission, the pilot operated valves have a stronger flow capacity than the direct drive valves with similar size. For example, the valve designed by Lantela et al can achieve a flow rate of 9 L/min with a 4 cm 3 volume [35].…”
Section: Pilot Operated Hsvmentioning
confidence: 99%