Seamless Healthcare Monitoring 2017
DOI: 10.1007/978-3-319-69362-0_6
|View full text |Cite
|
Sign up to set email alerts
|

Photoplethysmogram

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 138 publications
0
4
0
Order By: Relevance
“…Several investigators developed photoplethysmography imaging (PPGI) prototypes for testing and validation inside clinical setting [53]. The essential component of the PPGI system is a remote-based camera for visualizing superficial vascular networks and detecting blood volume changes in different areas of a measured object [42,54]. PPGI uses the same fundamental principle to improve on the poor spatial resolution inherent to conventional skin contact PPG.…”
Section: Contactless Neonatal Imaging Technologiesmentioning
confidence: 99%
See 1 more Smart Citation
“…Several investigators developed photoplethysmography imaging (PPGI) prototypes for testing and validation inside clinical setting [53]. The essential component of the PPGI system is a remote-based camera for visualizing superficial vascular networks and detecting blood volume changes in different areas of a measured object [42,54]. PPGI uses the same fundamental principle to improve on the poor spatial resolution inherent to conventional skin contact PPG.…”
Section: Contactless Neonatal Imaging Technologiesmentioning
confidence: 99%
“…Some examples of dynamic parameters include: capillary refill time, muscle pump efficacy, venous outflow, pulse characteristics (rate, variability, rhythm) [11,12,49], and arterial oxygen saturation. The main divergence between PPGI and PPG is in the composition of the measured light intensities and the number of elements used for detection [54,67].…”
Section: Contactless Neonatal Imaging Technologiesmentioning
confidence: 99%
“…The PPG waveform comprises DC and AC components. The DC component results from not only tissues and non-pulsatile components of blood but also ambient light [22]. This component limits the dynamic range of the PPG front-end input.…”
Section: Table I Control Bits Of the Led Driver And Corresponding Cur...mentioning
confidence: 99%
“…After that a number of researchers worked to solve the problem efficiently. In this context, a detailed review on the state-of-the-art of PPG based heart rate estimation techniques is presented in [13,15]. Additionally, Temko [17] proposed a heart rate estimation method where the wiener filter and phase vocoder are employed to remove motion artifacts from the PPG signals.…”
Section: Introductionmentioning
confidence: 99%