2021
DOI: 10.3390/pr9101761
|View full text |Cite
|
Sign up to set email alerts
|

Photolithographically Home-Made PVDF Sensor for Cavitation Impact Load Measurement

Abstract: Piezoelectric PVDF sensors offer a unique option for the measurement of cavitation aggressiveness represented by the magnitude of impacts due to cavitation bubble collapses near walls. The aggressiveness measurement requires specific sensor shape and area, whereas commercial PVDF sensors are fabricated in limited geometry and size ranges. The photolithography method offers a possibility of production of home-made PVDF sensors of arbitrary shape and size. The methodology of a unique application of the standard … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 13 publications
0
2
0
Order By: Relevance
“…Sensitivities of 1.368 V/N and 0.815 V/N with correlation coefficients of 0.986 and 0.969 by the linear fit were obtained for sensors based on alumina and mylar substrates, respectively. The results indicate that our sensors’ sensitivity is higher than that of a previous piezoelectric sensor (0.0758 V/N) [ 36 ]. Moreover, the sensitivity of the sensor on the alumina substrate was approximately 70% higher than that on the mylar substrate, indicating that the sensitivity varied significantly depending on the substrate material.…”
Section: Resultsmentioning
confidence: 67%
See 1 more Smart Citation
“…Sensitivities of 1.368 V/N and 0.815 V/N with correlation coefficients of 0.986 and 0.969 by the linear fit were obtained for sensors based on alumina and mylar substrates, respectively. The results indicate that our sensors’ sensitivity is higher than that of a previous piezoelectric sensor (0.0758 V/N) [ 36 ]. Moreover, the sensitivity of the sensor on the alumina substrate was approximately 70% higher than that on the mylar substrate, indicating that the sensitivity varied significantly depending on the substrate material.…”
Section: Resultsmentioning
confidence: 67%
“…The ball drop test was used to evaluate our sensor’s responses to the impact force, as shown in Figure 7 . The linearity of the response to the increasing force can be simply acquired and compared [ 34 , 35 , 36 , 37 ]. The voltage output of the sensor caused by the impact force of the ball was recorded by a digital oscilloscope (DSOX2014A, Keysight Technologies, Inc.).…”
Section: Resultsmentioning
confidence: 99%