2018
DOI: 10.1364/oe.26.033510
|View full text |Cite
|
Sign up to set email alerts
|

Phase measurement deflectometry with refraction model and its calibration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 34 publications
(15 citation statements)
references
References 21 publications
0
15
0
Order By: Relevance
“…In order to overcome the challenges in classical PMD, several different kinds of regularization approaches with corresponding setups for different requirements in actual measurement are proposed. [38][39][40][41][42][43][44][45][46][47][48] Some typical PMD establishments with additional components (such as screens or cameras) are shown in Fig. 3.…”
Section: Establishments Of Pmdmentioning
confidence: 99%
See 2 more Smart Citations
“…In order to overcome the challenges in classical PMD, several different kinds of regularization approaches with corresponding setups for different requirements in actual measurement are proposed. [38][39][40][41][42][43][44][45][46][47][48] Some typical PMD establishments with additional components (such as screens or cameras) are shown in Fig. 3.…”
Section: Establishments Of Pmdmentioning
confidence: 99%
“…[38][39][40] However, movement of the LCD screen increases the instability and measurement time of the system. To resolve the ill-posed problems, Li et al 41 presented a simplified PMD system using a transparent screen and an LCD screen, avoiding the movement of the LCD screen. In Li's system, the two screens can be fixed in a relatively free position and the ray of camera can pass through the transparent screen to an LCD screen.…”
Section: Establishments Of Pmdmentioning
confidence: 99%
See 1 more Smart Citation
“…However, screen movement increases complexity of system structure and measurement time of the system. With the development of display techniques, Li et al improved multi-screen based PMD by using a transparent screen [36]. The camera ray can pass through the transparent screen to a general displaying screen.…”
Section: Multi-screen Based Pmdmentioning
confidence: 99%
“…Phase shifting and phase unwrapping techniques are applied to obtain phase information [43,44]. Two groups of perpendicular fringe patterns are required to establish a phase rectangular coordinate system [29][30][31][32][33][34][35][36]45]. In order to suppress phase noise, each fringe pattern is captured several times to calculate the average [41,42,[47][48][49].…”
Section: Challenges and Further Developmentmentioning
confidence: 99%