Phase behavior of ASDs based on hydroxypropyl cellulose

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
23
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 17 publications
(24 citation statements)
references
References 60 publications
(26 reference statements)
1
23
0
Order By: Relevance
“…The CUR-MAG CM revealed an 8.4 °C negative deviation of T g from the theoretical value, indicating that there might be weak intermolecular interactions in CUR-MAG CM, which were further investigated by spectral analysis. The T g values of HPMC, HPC, and PVP K30 were determined to be 140.4 [ 10 ], 86.2 [ 47 ] and 176.0 °C [ 48 ], as previously reported, which were used to calculate the theoretical T g s of the ternary co-amorphous systems. When CUR-MAG CM was regarded as a single amorphous “component”, CUR-MAG-HPMC CM, CUR-MAG-HPC CM, and CUR-MAG-PVP K30 CM showed theoretical T g values of about 22.0, 21.9, and 22.0 °C, and their experimental T g values exhibited 4.1, 1.6, and 15.4 °C positive deviation from the theoretical values, respectively ( Figure 3 and Table 1 ).…”
Section: Resultsmentioning
confidence: 99%
“…The CUR-MAG CM revealed an 8.4 °C negative deviation of T g from the theoretical value, indicating that there might be weak intermolecular interactions in CUR-MAG CM, which were further investigated by spectral analysis. The T g values of HPMC, HPC, and PVP K30 were determined to be 140.4 [ 10 ], 86.2 [ 47 ] and 176.0 °C [ 48 ], as previously reported, which were used to calculate the theoretical T g s of the ternary co-amorphous systems. When CUR-MAG CM was regarded as a single amorphous “component”, CUR-MAG-HPMC CM, CUR-MAG-HPC CM, and CUR-MAG-PVP K30 CM showed theoretical T g values of about 22.0, 21.9, and 22.0 °C, and their experimental T g values exhibited 4.1, 1.6, and 15.4 °C positive deviation from the theoretical values, respectively ( Figure 3 and Table 1 ).…”
Section: Resultsmentioning
confidence: 99%
“…Unfortunately, our DSC method was not able to detect a T g for HPC SSL, which is a well-known issue of HPC. Therefore, we used a T g for HPC SSL which was recently published by Luebbert et al as a predicted T g of 81.8 °C ( Luebbert et al, 2020 ). Our DSC thermogram of HPC SSL can be found in the Supplementary Data (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…A temperature ramp from 90 • C to 200 • C is applied to investigate the effect of the temperature on the rheological behaviors of HPMC and HPC. The glass transition temperatures of HPMC HME 4M and HPC GXF are reported at 115 • C [31] and 84 • C [32], respectively; therefore, the temperature ramp tested is directly in the range of interest. The complex viscosity and tan δ as a function of the temperature are depicted in Figure 5.…”
Section: Dissolution and Semmentioning
confidence: 99%