2014
DOI: 10.1016/j.jpba.2013.08.048
|View full text |Cite
|
Sign up to set email alerts
|

Pharmacokinetics study of hemin in rats by applying 58Fe-extrinsically labeling techniques in combination with ICP-MS method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 27 publications
0
6
0
Order By: Relevance
“…The Gd content was analyzed with ICP-MS (Agilent 7500C, Agilent Technologies, Tokyo, Japan) [ 47 ]. The sample introduction system consisted of a robust Babington nebulizer with a Scott spray chamber (Agilent Technologies, Tokyo, Japan) cooled by a Peltier element (2 °C).…”
Section: Methodsmentioning
confidence: 99%
“…The Gd content was analyzed with ICP-MS (Agilent 7500C, Agilent Technologies, Tokyo, Japan) [ 47 ]. The sample introduction system consisted of a robust Babington nebulizer with a Scott spray chamber (Agilent Technologies, Tokyo, Japan) cooled by a Peltier element (2 °C).…”
Section: Methodsmentioning
confidence: 99%
“…These types of metabolic studies are clearly facilitated using several tracers. Other recent applications of elemental tracers in metabolic and metallomics studies include zinc, 73 iron 74 and selenium. 75 Other applications are reviewed elsewhere.…”
Section: Applications Of Isotopic Measurementsmentioning
confidence: 99%
“…69 The central peak in the chromatogram at mass 80 represents the selenosugar. The tracer used here was 74 Se; it was added post-column at a constant ow rate throughout the chromatographic process. A small negative peak observed in the dead volume of the chromatographic system was due to the elution of the matrix components from the sample.…”
Section: Total Elemental Analysis By Idmsmentioning
confidence: 99%
“…The MeP and MeP-NPs pharmacokinetics study was accomplished using randomly divided rat groups (n = 3). Blood samples (50 µL) were collected before injection and after at different time points: 0.25, 0.50, 1.0, 3.0, 6.0, 24.0, and 48.0 h. The blood samples were diluted to 1.0 mL and analyzed with ICP-MS (Agilent 7500C, Agilent Technologies, Tokyo, Japan) [112]. The sample introduction system consisted of a robust Babington nebulizer with a Scott spray chamber (Agilent Technologies, Tokyo, Japan) cooled by a Peltier element (2 • C).…”
Section: In Vivo Pharmacokinetic Studymentioning
confidence: 99%