2019
DOI: 10.1016/j.survophthal.2019.06.007
|View full text |Cite
|
Sign up to set email alerts
|

Phacoemulsification in review: Optimization of cataract removal in an in vitro setting

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 19 publications
(14 citation statements)
references
References 36 publications
0
14
0
Order By: Relevance
“…It is also important to note that the decrease in incidence over time throughout this study may be due to improvements in phacoemulsification technologies and more efficient phacodynamics. 13 Three out of five surgeons used the Divide-and-Conquer phacoemulsification technique while two out of five used the Horizontal Chop, with no statistically significant difference between the two techniques (p = 0.71). These findings suggest that while some patient-specific biometric characteristics have proven to be significant risk factors, surgeon-specific operative habits (not including phacoemulsification technique) may also be associated with retained lens fragments in the anterior chamber.…”
Section: Discussionmentioning
confidence: 88%
“…It is also important to note that the decrease in incidence over time throughout this study may be due to improvements in phacoemulsification technologies and more efficient phacodynamics. 13 Three out of five surgeons used the Divide-and-Conquer phacoemulsification technique while two out of five used the Horizontal Chop, with no statistically significant difference between the two techniques (p = 0.71). These findings suggest that while some patient-specific biometric characteristics have proven to be significant risk factors, surgeon-specific operative habits (not including phacoemulsification technique) may also be associated with retained lens fragments in the anterior chamber.…”
Section: Discussionmentioning
confidence: 88%
“…Phacoemulsification devices and technologies have been developing every day. [12][13][14][15][16] Active Sentry handpiece, one of the innovations of the Centurion Vision System, functions with the active fluidics system and carries an integrated sensor. This system has many advantages.…”
Section: Discussionmentioning
confidence: 99%
“…[ 26 27 ] Other factors that may contribute to the overall reduction in the incidence of RLFs are the improvements in phacoemulsification technologies and more efficient phacodynamics over time. [ 28 ]…”
Section: Discussionmentioning
confidence: 99%