Pervaporation Removal of Pyridine from Saline Pyridine/Water Effluents Using PEBA-2533 Membranes: Experiment and Simulation

Abstract: Pervaporation technology using PEBA-2533 membranes was investigated to separate a low concentration of pyridine from the ternary mixture of pyridine, water, and NaCl. The experimental results showed that the studied membrane could achieve the enrichment of pyridine and the rejection of NaCl simultaneously. The permeation of pyridine was driven by the temperature and pyridine concentration in the feed solution. The experimental results for the effect of NaCl content on the fluxes correlated with the simulation … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 63 publications
(139 reference statements)
0
5
0
Order By: Relevance
“…In the NVT -MD simulation, a hydrogen bond script was used for each swelling model to automatically obtain the number of hydrogen bonds formed between phenol and water within the range of hydrogen bond action. 45 As such, the relationship between the swelling degree and the hydrogen bonds is plotted in Fig. 3.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…In the NVT -MD simulation, a hydrogen bond script was used for each swelling model to automatically obtain the number of hydrogen bonds formed between phenol and water within the range of hydrogen bond action. 45 As such, the relationship between the swelling degree and the hydrogen bonds is plotted in Fig. 3.…”
Section: Resultsmentioning
confidence: 99%
“…Since the sample contained only water and phenol, after determining the water content, the phenol content in the sample could also be determined. 45…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the current detection methods require sophistically instruments and tedious procedures. [3,4] Py can be removed via adsorption [2,[5][6][7][8][9][10] and degradation (via ozonation, [11] electrochemical, [12] atmospheric DC water plasma, [13] or biological biodegradation, [14,15] electrical bio-photodegradation, [16] or microbial fuel cells [17] ) methods. Some of those adsorbents require toxic reagents such as heavy metals.…”
Section: Introductionmentioning
confidence: 99%