Perfusion Index and ultrasonography in the evaluation of infraclavicular block

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 19 publications
0
9
0
Order By: Relevance
“…Regional haemodynamic parameters were measured by pulsed-wave Doppler (PWD) ultrasound (M7 super, Mindray Medical International, China) with a 12–4 MHz linear array transducer. 3 6 We defined the location of the anterior tibial artery (ATA) as 1 cm proximal to the extensor retinaculum ( figure 2A ). The location of the posterior tibial artery (PTA) was defined to be halfway between the posterior border of the medial malleolus and the Achilles tendon ( figure 2B ).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Regional haemodynamic parameters were measured by pulsed-wave Doppler (PWD) ultrasound (M7 super, Mindray Medical International, China) with a 12–4 MHz linear array transducer. 3 6 We defined the location of the anterior tibial artery (ATA) as 1 cm proximal to the extensor retinaculum ( figure 2A ). The location of the posterior tibial artery (PTA) was defined to be halfway between the posterior border of the medial malleolus and the Achilles tendon ( figure 2B ).…”
Section: Methodsmentioning
confidence: 99%
“…At each time point, we obtained US and PI data before conducting the pinprick sensory tests. We performed the pinprick sensory tests with a 24-gauge blunt needle on the skin innervated by the sciatic nerve and evaluated the findings using the Hollmen scale 3 ((0) normal transmission using the pinprick test; (1) needle sensed less than the contralateral extremity; (2) feeling the needle as a blunt object; (3) loss of tactile sense). We also recorded the non-invasive BP and HR at each time point.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…in 40 patients who underwent an infraclavicular block, they monitored the Perfusion index (Pi) and regional hemodynamic parameters in the ipsilateral limb. 67 ten minutes after the block execution, Doppler parameters were valid to confirm its success or failure due to the sympathectomy effect. Needles visibility during ultrasound-guided peripheral nerve blocks is vital for procedural success and prevention of possible side effects and complications.…”
Section: Regional Anesthesiamentioning
confidence: 99%