2017
DOI: 10.1016/j.applthermaleng.2017.03.058
|View full text |Cite
|
Sign up to set email alerts
|

Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 47 publications
(8 citation statements)
references
References 33 publications
0
8
0
Order By: Relevance
“…Su et al [16] proposed a solarpowered absorption chiller combined with a liquid desiccant dehumidifier for space cooling and fresh water production, and their results reveals that the exergy efficiency for the proposed system is 2.97% higher than the reference system. Huang et al [17,18] studied the conjugate heat and mass transfer in a membrane parallel-plate contractor, and analysed the effects of local and mean friction factors, Nusselt number and Sherwood number. Apart from the dehumidifier in the dehumidification system, the regenerator is another crucial component since the diluted solution needs to be re-concentrated in the regenerator.…”
Section: Research Backgroundmentioning
confidence: 99%
“…Su et al [16] proposed a solarpowered absorption chiller combined with a liquid desiccant dehumidifier for space cooling and fresh water production, and their results reveals that the exergy efficiency for the proposed system is 2.97% higher than the reference system. Huang et al [17,18] studied the conjugate heat and mass transfer in a membrane parallel-plate contractor, and analysed the effects of local and mean friction factors, Nusselt number and Sherwood number. Apart from the dehumidifier in the dehumidification system, the regenerator is another crucial component since the diluted solution needs to be re-concentrated in the regenerator.…”
Section: Research Backgroundmentioning
confidence: 99%
“…Cho et al [8] conducted a series of experiments and found that the cross-flow liquid desiccant dehumidifier has stable dehumidification performance regardless of the variations in operating parameters, but the crossflow dehumidifier performance is effected by temperature and humid process air conditions. Bai et al [9] experimentally investigated the performance of the membrane-based liquid desiccant dehumidification system with calcium chloride. The sensible, latent and total effectiveness in their study were recorded as 0.49, 0.55, and 0.53, respectively.…”
Section: E-mail Addressesmentioning
confidence: 99%
“…Moghaddam et al [23] introduced a solution-side effectiveness to evaluate the impact of * on dehumidification and regeneration processes, and pointed out that the latent effectiveness difference between the air-side and the solution-side is can be neglected. Bai et al [24,25] experimentally and theoretically studied the operating characters of a parallel-plate membrane-based dehumidification system by focusing on various parameters, and identified the effects of and mass flow rate ratio ( * ) are interacted with each other. Some researchers developed different types of the membrane-based contractor.…”
Section: Introductionmentioning
confidence: 99%