2009
DOI: 10.1088/1748-0221/4/06/p06009
|View full text |Cite
|
Sign up to set email alerts
|

Performance studies of the CMS Strip Tracker before installation

Abstract: am P.C. Bhat, am K. Burkett, am S. Cihangir, am O. Gutsche, am H. Jensen, am M. Johnson, am N. Luzhetskiy, am D. Mason, am T. Miao, am S. Moccia, am C. Noeding, am A. Ronzhin, am E. Skup, am W.J. Spalding, am L. Spiegel, am S. Tkaczyk, am F. Yumiceva, am A. Zatserklyaniy, am E. Zerev, am I. Anghel, an V.

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
14
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(15 citation statements)
references
References 13 publications
(20 reference statements)
1
14
0
Order By: Relevance
“…Figure 7 shows examples of the evolution of the aligned positions and the alignment parameters calculated by the HIP algorithm after every iteration. We observe reasonable convergence for the coordinates that are expected to be most precisely determined (see section 4.3) and a stable result in subsequent iterations using zero APE. Results of the first HIP alignment step (TOB modules only) on the C −10 TIF data sample.…”
Section: Hip Algorithmsupporting
confidence: 51%
See 1 more Smart Citation
“…Figure 7 shows examples of the evolution of the aligned positions and the alignment parameters calculated by the HIP algorithm after every iteration. We observe reasonable convergence for the coordinates that are expected to be most precisely determined (see section 4.3) and a stable result in subsequent iterations using zero APE. Results of the first HIP alignment step (TOB modules only) on the C −10 TIF data sample.…”
Section: Hip Algorithmsupporting
confidence: 51%
“…Track reconstruction and performance specific to the Tracker Integration Facility configuration are discussed in detail in refs. [3,4].…”
Section: Charged Particle Tracksmentioning
confidence: 99%
“…Additionally a software calibration is obtained using the nominal correspondence of a tick mark to a charge deposit of 175 000 e − . The estimated systematic uncertainty is 5%, attributable to the sensitivity of the tick mark amplitude to variations in the LV power supply and environmental temperature [15].…”
Section: Readout Calibrationmentioning
confidence: 99%
“…Additionally a software calibration is obtained by using the nominal correspondence of a tick mark to a charge deposit of 175 000 e − . The estimated systematic uncertainty is 5%, attributable to the sensitivity of the tick mark amplitude to variations in the LV power supply and environmental temperature [12].…”
Section: System Commissioning and Calibrationmentioning
confidence: 99%