2003
DOI: 10.1016/s0925-4005(03)00113-8
|View full text |Cite
|
Sign up to set email alerts
|

Performance of the Spreeta 2000 integrated surface plasmon resonance affinity sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

5
101
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 166 publications
(106 citation statements)
references
References 6 publications
5
101
0
Order By: Relevance
“…In angular or spectral interrogation methods, the determination of SPR dip position involves a series of intensity data from different incident angles or wavelengths, and the abundance of data has helped to suppress the intensity noise and greatly improve the signal to noise ratio. Thus, the refractive index resolution in both modulation methods has been improved down to 10 −6 level [36,31]. Various averaging and mathematical treatment methods can be further used to lower the detection limit down to 10 −7 RIU level [31,30].…”
Section: Surface Plasmon Resonance: Phase Vs Amplitudementioning
confidence: 99%
See 2 more Smart Citations
“…In angular or spectral interrogation methods, the determination of SPR dip position involves a series of intensity data from different incident angles or wavelengths, and the abundance of data has helped to suppress the intensity noise and greatly improve the signal to noise ratio. Thus, the refractive index resolution in both modulation methods has been improved down to 10 −6 level [36,31]. Various averaging and mathematical treatment methods can be further used to lower the detection limit down to 10 −7 RIU level [31,30].…”
Section: Surface Plasmon Resonance: Phase Vs Amplitudementioning
confidence: 99%
“…Thus, the refractive index resolution in both modulation methods has been improved down to 10 −6 level [36,31]. Various averaging and mathematical treatment methods can be further used to lower the detection limit down to 10 −7 RIU level [31,30]. The angular or wavelength modulation method, however, requires a linear detector for refractive index measurement of a single point on the SPR cell.…”
Section: Surface Plasmon Resonance: Phase Vs Amplitudementioning
confidence: 99%
See 1 more Smart Citation
“…This change in refractive index is measured in real time, and the result is plotted as response or resonance units (RUs) versus time (a sensorgram) 25 . The miniature SPR sensing chip, described by Soelberg 26 , et al and Chinowsky 27,28 , et al, is a fully integrated SPR sensor element. Its main components ( Fig.…”
Section: Gold Nanoparticle-enhanced Surface-plasmonmentioning
confidence: 99%
“…SPR has been involved in many applications in engineering, biotechnology, and other life science disciplines. In the past two decades, SPR had played a vital role in many promising sensing applications in biological and chemical systems [11][12][13][14][15]. Recently, LC coupled with SPR phenomenon has been widely utilized in sensing applications.…”
mentioning
confidence: 99%