Performance of the RAD-57 Pulse Co-Oximeter Compared With Standard Laboratory Carboxyhemoglobin Measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

2
54
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 71 publications
(57 citation statements)
references
References 7 publications
2
54
1
Order By: Relevance
“…Non-invasive and continuous measurement of COHb can be provided by pulse CO-oximeter but this device is shown to produce large error in the estimated value of 14%. 2 Meanwhile, fast and non-invasive measurement of arterial blood OxyHb saturation (SO 2 ) can be provided by pulse oximetry, but its high accuracy is limited to SO 2 greater than 70%. Techniques that are able to provide fast and accurate measurement of percent saturation of oxygen and CO in blood are of signi¯cant value, especially to individuals who are occupationally exposed to incomplete combustion of organic materials such as that of coal-¯red power plant operators and¯re¯ghters.…”
Section: Introductionmentioning
confidence: 99%
“…Non-invasive and continuous measurement of COHb can be provided by pulse CO-oximeter but this device is shown to produce large error in the estimated value of 14%. 2 Meanwhile, fast and non-invasive measurement of arterial blood OxyHb saturation (SO 2 ) can be provided by pulse oximetry, but its high accuracy is limited to SO 2 greater than 70%. Techniques that are able to provide fast and accurate measurement of percent saturation of oxygen and CO in blood are of signi¯cant value, especially to individuals who are occupationally exposed to incomplete combustion of organic materials such as that of coal-¯red power plant operators and¯re¯ghters.…”
Section: Introductionmentioning
confidence: 99%
“…These results contrast sharply with Touger et al, who found few false positives but several false negatives. 17 Although Weaver did not report on the rate of screening false negatives, a concerning finding in this study is the nature of these false negatives. Even when the device detected a case of occult CO toxicity, the S pCO reading was 13% while the COHb was 19%.…”
mentioning
confidence: 75%
“…Specifically, the S pCO under-estimated COHb in all cases, with 2 S pCO values falling into the range that would not have supported a diagnosis of CO poisoning (2% and 4%). Moreover, the precision of the Rad-57 appears to decrease as the COHb increases, 12,17,19 despite the manufacturer's assertion that the accuracy is Ϯ 3% up to a COHb of 40%. 8 -10 While several studies have found that the Rad-57 is likely to systematically overestimate the COHb, as compared to blood levels, 17,19,[23][24][25] Weaver found repeated underestimation by the device.…”