Performance of a Volatile Corrosion Inhibitor for Mitigating Corrosion Under Insulation

Abstract: This study evaluated the efficacy of a commercial volatile corrosion inhibitor (VCI) in mitigating the corrosion of carbon steel insulated with mineral wool insulation, especially as a retrofitted solution to CUI management. When VCI was added in dry insulation before the test solution was introduced, severity of CUI was reduced after 14-day exposure. However, when the exposure time was extended to 90 days, no significant mitigation effect was observed. Furthermore, VCI was ineffective when added to pre-corrod… Show more