2014
DOI: 10.1063/1.4880724
|View full text |Cite
|
Sign up to set email alerts
|

Performance of a beam-multiplexing diamond crystal monochromator at the Linac Coherent Light Source

Abstract: A double-crystal diamond monochromator was recently implemented at the Linac Coherent Light Source. It enables splitting pulses generated by the free electron laser in the hard x-ray regime and thus allows the simultaneous operations of two instruments. Both monochromator crystals are High-Pressure High-Temperature grown type-IIa diamond crystal plates with the (111) orientation. The first crystal has a thickness of ∼100 μm to allow high reflectivity within the Bragg bandwidth and good transmission for the oth… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
40
0
2

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
2

Relationship

5
4

Authors

Journals

citations
Cited by 67 publications
(42 citation statements)
references
References 38 publications
(34 reference statements)
0
40
0
2
Order By: Relevance
“…) but most importantly allows multiplexing with another instrument located downstream in the FEH (Feng et al, 2013(Feng et al, , 2015Zhu et al, 2014). A detailed discussion concerning the effect of the monochromaticity on the intensity and longitudinal coherence properties of a FEL SASE beam is provided by Lee et al (2012).…”
Section: à5mentioning
confidence: 99%
See 1 more Smart Citation
“…) but most importantly allows multiplexing with another instrument located downstream in the FEH (Feng et al, 2013(Feng et al, , 2015Zhu et al, 2014). A detailed discussion concerning the effect of the monochromaticity on the intensity and longitudinal coherence properties of a FEL SASE beam is provided by Lee et al (2012).…”
Section: à5mentioning
confidence: 99%
“…For experiments that require a monochromatic beam [i.e. a larger longitudinal coherence length l = 2 =Á = ðE=ÁEÞ] but do not intend to scan broadly the incident energy, a custom-built (JJ X-ray, Denmark) largeoffset Double-Crystal Monochromator (DCM) (Zhu et al, 2014) is located 44 m upstream of the sample. In this configuration all components located downstream of the dashed line are translated 600 mm horizontally as displayed in Fig.…”
Section: Instrument Overviewmentioning
confidence: 99%
“…[23]), with the XPP diamond monochromator inserted [24]. The use of the monochromator removes the chromaticity effect of the CRLs, with a tradeoff of reduced overall intensity as well as 100% intensity fluctuations due to the nature of the self-amplified spontaneous emission (SASE) spectrum.…”
Section: Research Articlementioning
confidence: 99%
“…Pulseto-pulse intensity variations led to large imprint size variations (Lemke et al, 2013b;Zhu et al, 2014). The two single-shot imprints shown were among the smallest obtained on the target.…”
Section: Comparison and Discussionmentioning
confidence: 99%