Performance of a 250 kW Organic Rankine Cycle System for Off-Design Heat Source Conditions

Abstract: An organic Rankine cycle system comprised of a preheater, evaporator, condenser, turbine, generator, and pump was used to study its off-design performance and the operational control strategy. R245fa was used as the working fluid. Under the design conditions, the net power output is 243 kW and the system thermal efficiency is 9.5%. For an off-design heat source flow rate (m W ), the operating pressure was controlled to meet the condition that the R245fa reached the liquid and vapor saturation states at the out… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 17 publications
(29 reference statements)
0
6
0
Order By: Relevance
“…The working fluid properties were evaluated using the built-in thermo-physical properties database of Thermolib. To validate the developed Thermolib simulation model, comparisons between the present model results and those obtained from Fu et al [32] were performed by setting the same operating conditions and using the same working fluid, i.e., R245fa. The mass flow rate of R245fa was kept at a fixed value of 11.85 kg/s.…”
Section: Results and Discusstionsmentioning
confidence: 99%
See 1 more Smart Citation
“…The working fluid properties were evaluated using the built-in thermo-physical properties database of Thermolib. To validate the developed Thermolib simulation model, comparisons between the present model results and those obtained from Fu et al [32] were performed by setting the same operating conditions and using the same working fluid, i.e., R245fa. The mass flow rate of R245fa was kept at a fixed value of 11.85 kg/s.…”
Section: Results and Discusstionsmentioning
confidence: 99%
“…The comparisons were carried out for a range of the heat source mass flow rates of 10.0-25.0 kg/s. The present model results and those obtained from [32] for the variations of the system efficiency with the heat source mass flow rate are shown in Table 4. It can be seen that the predicted results from the present model and those published in [32] are in very good agreement.…”
Section: Results and Discusstionsmentioning
confidence: 99%
“…However, for smaller systems (<10 kW) and scroll type (<100 kW), screw-type expanders are used and results are available in the literature for these smaller size ORCs, but these systems cannot be compared with the present study. 19,35 F I G U R E 1 4 The power output of an ORC system in three distinct scenarios plotted against the refrigerant pressure.…”
Section: Comparative Studymentioning
confidence: 99%
“…The techno‐economic feasibility analysis of an ORC power system for waste heat recovery is also performed. Furthermore, a comparative analysis is performed with a previous study on a 250‐kW ORC system 19 …”
Section: Introductionmentioning
confidence: 99%
“…The majority of application areas experience variations in thermal resource (or cooling processes) over time and the system should adapt to the working regime to ensure optimum performance. There are few studies related to control aspects and off-design performance of ORC systems [23][24][25][26][27][28][29][30][31][32][33][34][35]. Thus, all the following studies are related to low temperature ORCs.…”