PESC Record. 27th Annual IEEE Power Electronics Specialists Conference
DOI: 10.1109/pesc.1996.548708
|View full text |Cite
|
Sign up to set email alerts
|

Performance of a 10 kW power electronic interface for combined wind/PV isolated generating systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
35
0

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 86 publications
(35 citation statements)
references
References 0 publications
0
35
0
Order By: Relevance
“…Early MISO converters were constructed by stacking multiple SISO converters with their output capacitors connected in series and both converters sharing a lone output. Such an example was built by the University of Rome in 1996 with two inputs and a shared output [12]. This design, while novel for its time, struggles to regulate its output voltage effectively whenever one of the two input sources falls out of operation, which is due to large input voltage variation [13].…”
Section: Multiple Input Single Output Convertersmentioning
confidence: 99%
“…Early MISO converters were constructed by stacking multiple SISO converters with their output capacitors connected in series and both converters sharing a lone output. Such an example was built by the University of Rome in 1996 with two inputs and a shared output [12]. This design, while novel for its time, struggles to regulate its output voltage effectively whenever one of the two input sources falls out of operation, which is due to large input voltage variation [13].…”
Section: Multiple Input Single Output Convertersmentioning
confidence: 99%
“…Generally, PV power and wind power are complementary since sunny days are usually calm and strong winds are often occurred at cloudy days or at night time. Hence, the hybrid PV/wind power system therefore has higher reliability to deliver continuous power than either individual source [4], [5].But the size and components are made the system to complex and high cost.…”
Section: Introductionmentioning
confidence: 99%
“…In the recent decade, PV is getting more attractive because it has no noise, no installation area limitation and no additional maintenance cost [1]. In order to combine several input resources, series-connected PV module string [2] is conventionally used. However PV string has the drawback of power limit due to a limit number of series connections in order to increase the nominal power [1].…”
Section: Introductionmentioning
confidence: 99%