2018
DOI: 10.1016/j.matpr.2018.06.272
|View full text |Cite
|
Sign up to set email alerts
|

Performance Improvement of Simple Gas Turbine Cycle with Vapor Compression Inlet Air Cooling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(9 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…The possibility of erosion and corrosion when water is sprayed with air in the inlet of the gas turbine is a limiting factor, even if it is very small [15]. Since the compressor is an essential component of the gas turbine, it directly affects the production of the plant, therefore the technology of cooling air entering the compressor can be used [16][17][18][19][20][21][22][23]. Barakat et al [24] they tested a hybrid cooling system that included an underground heat exchanger.…”
Section: Introductionmentioning
confidence: 99%
“…The possibility of erosion and corrosion when water is sprayed with air in the inlet of the gas turbine is a limiting factor, even if it is very small [15]. Since the compressor is an essential component of the gas turbine, it directly affects the production of the plant, therefore the technology of cooling air entering the compressor can be used [16][17][18][19][20][21][22][23]. Barakat et al [24] they tested a hybrid cooling system that included an underground heat exchanger.…”
Section: Introductionmentioning
confidence: 99%
“…18,19 The annual ∑CDH and cooling load profiles were investigated depending on the ambient temperature and humidity distribution. 18,20,21 A sinusoidal distribution of ambient temperature was proposed. 6,22…”
Section: Introductionmentioning
confidence: 99%
“…18,19 The annual P CDH and cooling load profiles were investigated depending on the ambient temperature and humidity distribution. 18,20,21 A sinusoidal distribution of ambient temperature was proposed. 6,22 In reality, any estimation method, used in thermal technologies and issuing from annual (monthly, seasonal) effect, based on the "hour-by-hour" or other time step by step calculation procedure to take into account actual varying site climatic conditions might be considered as based on cooling/heating degree hour (C/ HDH) numbers.…”
Section: Introductionmentioning
confidence: 99%
“…Their application is quite effective in gas turbines of combined cycle with steam injection and based on them power plants. 48,49 A design refrigeration capacity of the cooling systems should be selected to cover the current needs and provide a closed to maximum annual effect avoiding oversizing. 50,51 A lot of researches deal with rational sizing the cooling systems 52,53 including cooling towers.…”
Section: Introductionmentioning
confidence: 99%
“…Their application is quite effective in gas turbines of combined cycle with steam injection and based on them power plants. 48,49…”
Section: Introductionmentioning
confidence: 99%