Performance estimation of interior permanent-magnet brushless motors using the voltage-driven flux-MMF diagram

Abstract: The flux-magnetomotive force (flux-MMF) diagram, or "energy conversion loop," is a powerful tool for computing the parameters of saturated interior permanent-magnet brushless motors, especially when the assumptions underlying classical dq theory are not valid, as is often the case in modern practice. Efficient finite-element computation of the flux-MMF diagram is possible when the motor current is known a priori, but in high-speed operation the current regulator can lose control of the current waveform and the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 43 publications
(24 citation statements)
references
References 13 publications
(24 reference statements)
0
24
0
Order By: Relevance
“…It is well known that in order to accurately model behavior of a healthy IPM machine, a mapping of flux-linkages to current is needed [38], [28]. This non-linear flux linkage map can capture most of the behavior of the machine including the magnetic saturation, spatial saliency and harmonics [28]-[31].…”
Section: Proposed Fault Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…It is well known that in order to accurately model behavior of a healthy IPM machine, a mapping of flux-linkages to current is needed [38], [28]. This non-linear flux linkage map can capture most of the behavior of the machine including the magnetic saturation, spatial saliency and harmonics [28]-[31].…”
Section: Proposed Fault Modelmentioning
confidence: 99%
“…In [10] and [27] an inductance based model was proposed for inter-turn fault detection in PM synchronous machines. However, IPM machines with buried magnets exhibits high level of magnetic saturation and cross-saturation effects and therefore separation of armature reaction flux linkage from the total flux linkage will incur large error and hence compromises model accuracy [28]- [33]. Moreover the method of extraction of inductances reported in [27] and [34] by energy-perturbation is computationally more demanding requiring twice as many FE computations [32].…”
Section: Nomenclaturementioning
confidence: 99%
See 1 more Smart Citation
“…Numerical calculation can be achieved by using static magnetic field or transient magnetic field. Experimental measurement can be done by using off-line measurement, such as direct load method, voltage integration method and current decay method, as well as on-line identification [6][7].…”
Section: Introductionmentioning
confidence: 99%
“…If a calculation of nonlinear parameters was exactly performed, it is known as a efficient method [1]- [2].…”
Section: Introductionmentioning
confidence: 99%