2011
DOI: 10.1016/j.applthermaleng.2011.05.026
|View full text |Cite
|
Sign up to set email alerts
|

Performance enhancement of a thermally activated cooling system using microchannel heat exchangers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(9 citation statements)
references
References 40 publications
0
9
0
Order By: Relevance
“…[168,169]. However, the design of more compact and lighter heat exchangers plays a very important role, particularly in the emerging field of mobile applications.…”
Section: Future Scenariosmentioning
confidence: 99%
See 1 more Smart Citation
“…[168,169]. However, the design of more compact and lighter heat exchangers plays a very important role, particularly in the emerging field of mobile applications.…”
Section: Future Scenariosmentioning
confidence: 99%
“…However, the design of more compact and lighter heat exchangers plays a very important role, particularly in the emerging field of mobile applications. To this end, several heat transfer enhancement techniques are investigated, leading to new concepts such as microchannel [168,170,171] and porous [172,173] heat exchangers. The addition of nanoparticles to the working fluid might be beneficial for ORC power system for which ultra-high heat transfer to and from the working fluid is relevant [174].…”
Section: Future Scenariosmentioning
confidence: 99%
“…The actual heat transfer effectiveness of the recuperator was significantly higher than the designed value of 85% due to a relatively conservative design approach. 31 The thermally activated cooling system with integrated microchannels achieved a heat flux of over 5 kW with an overall coefficient of performance equal to 0.8. The thermally activated systems offer various advantages such as higher energy efficiency, higher indoor air quality, lower air emissions, and lower peak electricity demand.…”
Section: Industrial and Engineering Chemistry Researchmentioning
confidence: 99%
“…However, a simplified design model is desired within an acceptable error range. Wang and Peterson proposed a simplified model (without considering conjugate heat transfer and entrance effects) for a new thermally activated cooling system made by integrating an organic Rankine cycle and vapor compression cooling cycle . The thermally activated cooling system and integrated microchannel boiler/recuperator (374.65 × 133.35 × 66.294 mm) are shown in Figure .…”
Section: Qualitative Analysis Of Emerging C-mhx Technologiesmentioning
confidence: 99%
See 1 more Smart Citation