Performance Characteristics of a Novel Tandem Mass Spectrometry Assay For Serum Testosterone

Abstract: Background: Commercial immunoassays for testosterone (Te) may give inaccurate results for samples from women and children, leading to misdiagnosis and inappropriate treatment. We developed a sensitive and specific tandem mass spectrometric assay for measurement of Te at the concentrations encountered in women and children. Methods: Te was extracted with methyl tert-butyl ether from 100 L of serum or plasma, derivatized to form an oxime, and reextracted by solid-phase extraction. Instrumental analysis was perfo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
97
1
2

Year Published

2008
2008
2019
2019

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 150 publications
(104 citation statements)
references
References 43 publications
(29 reference statements)
4
97
1
2
Order By: Relevance
“…Briefly, steroids were extracted from samples and CORT, DHEA, A4, Pregn, and PROG were derivatized with hydroxylamine to form oxime derivatives; E1, E2 and E3 were derivatized with dansyl chloride to form dansyl derivatives. Limit of quantification (LOQ) was 0.05 ng/ml for Pregn, 1 ng/ml for PROG, 0.5 ng/mL for CORT, 0.01 for Te and A4 and 0.05 ng/ml for DHEA,1 pg/ml for E1, E2 and E3 [45]. The intra-assay and inter-assay CV were < 8 and 11%, respectively [47].…”
Section: Liquid Chromatography Tandem Mass Spectrometrymentioning
confidence: 97%
See 1 more Smart Citation
“…Briefly, steroids were extracted from samples and CORT, DHEA, A4, Pregn, and PROG were derivatized with hydroxylamine to form oxime derivatives; E1, E2 and E3 were derivatized with dansyl chloride to form dansyl derivatives. Limit of quantification (LOQ) was 0.05 ng/ml for Pregn, 1 ng/ml for PROG, 0.5 ng/mL for CORT, 0.01 for Te and A4 and 0.05 ng/ml for DHEA,1 pg/ml for E1, E2 and E3 [45]. The intra-assay and inter-assay CV were < 8 and 11%, respectively [47].…”
Section: Liquid Chromatography Tandem Mass Spectrometrymentioning
confidence: 97%
“…Plasma samples were analysed for Pregn, CORT, DHEA, A4, Te, PROG, E1, E2 and E3 using liquid chromatography tandem mass spectrometry methods (LC-MS/MS) as previously described [45][46][47]. Briefly, steroids were extracted from samples and CORT, DHEA, A4, Pregn, and PROG were derivatized with hydroxylamine to form oxime derivatives; E1, E2 and E3 were derivatized with dansyl chloride to form dansyl derivatives.…”
Section: Liquid Chromatography Tandem Mass Spectrometrymentioning
confidence: 99%
“…Functional groups commonly targeted for the derivatization of endogenous steroids are keto and hydroxyl groups (Anari et al, 2002;Xu et al, 2004;Kushnir et al, 2006aKushnir et al, ,b, 2008; and the gain in the sensitivity in methods that use chemical derivatization can be up to few orders of magnitude.…”
Section: B Sample Preparationmentioning
confidence: 99%
“…Derivatization proved to be useful in the high-throughput screening of acylcarnitines (Millington et al, 1989), amino acids (Chace et al, 1993), and organic acids (Johnson, 1999); high-throughput quantitative analysis of methylmalonic acid (MMA) (Kushnir et al, 2001;Kushnir, Rockwood, & Nelson, 2004); to reduce the sample volume required for the analysis of endogenous steroids (Kushnir et al, 2006a(Kushnir et al, ,b, 2008; and in cases when very limited samples are available for analysis (Kushnir et al, 2009). …”
Section: Lc-ms/ms In Clinical Diagnosticsmentioning
confidence: 99%
“…Several LC-MS/MS methods have been described for the quantification of testosterone in serum/plasma to overcome this problem (Cawood et al, 2005;Ismail et al, 2002;Kushnir et al, 2006a;Moal et al, 2007;Rauh et al, 2006;Singh, 2008;Taieb et al, 2003).…”
Section: Testosteronementioning