2015
DOI: 10.1016/j.compeleceng.2015.07.012
|View full text |Cite
|
Sign up to set email alerts
|

Performance and cooling efficiency of thermoelectric modules on server central processing unit and Northbridge

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0
1

Year Published

2019
2019
2022
2022

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(14 citation statements)
references
References 17 publications
0
13
0
1
Order By: Relevance
“…Yousefi et al, [42] / The 90 o inclination has the highest thermal resistance Jajja et al, [43] / The heat transfer coefficient for 0.2 mm fin spacing heat sink is considerably higher than the other geometries Putra et al, [44] / The used of coral as wick structured can improve the performance of heat transfer while decrease the CPU temperature for 38.6 % at the maximum heat load compared to a conventional copper heat sink. Tan & Demirel [45] / The temperature difference of 5°C reveals that the thermoelectric cooler is more effective than the water-cooling system. Muszynski & Andrzejczyk [46] / The hybrid microjet -microchannel module has higher heat removal compare to the traditional heat sink with forced air convection.…”
Section: Methods Of Liquid Cooling System For Cpumentioning
confidence: 99%
See 2 more Smart Citations
“…Yousefi et al, [42] / The 90 o inclination has the highest thermal resistance Jajja et al, [43] / The heat transfer coefficient for 0.2 mm fin spacing heat sink is considerably higher than the other geometries Putra et al, [44] / The used of coral as wick structured can improve the performance of heat transfer while decrease the CPU temperature for 38.6 % at the maximum heat load compared to a conventional copper heat sink. Tan & Demirel [45] / The temperature difference of 5°C reveals that the thermoelectric cooler is more effective than the water-cooling system. Muszynski & Andrzejczyk [46] / The hybrid microjet -microchannel module has higher heat removal compare to the traditional heat sink with forced air convection.…”
Section: Methods Of Liquid Cooling System For Cpumentioning
confidence: 99%
“…TEC is widely being used for cooling CPU to increase the CPU cooling performance while decreasing the noise of the cooling system. The application of TEC could reduce the noise to less than 40dB with a power consumption of 130 W to cool the CPU in Kumar et al, [45]. As the TEC is a very simple yet high cooling performance device, researchers are interested to combine with different cooling applications.…”
Section: Thermoelectric Coolers (Tecs)mentioning
confidence: 99%
See 1 more Smart Citation
“…The thermoelectric refrigeration system was first applied in the fields of military, aerospace, and medicine 25 . Subsequently, it has been gradually applied to the civil sector, such as in refrigerators, 26‐28 air‐conditioners, 29‐31 and computers 32 . In recent years, TEC technology has also been introduced to the field of BTMS.…”
Section: Introductionmentioning
confidence: 99%
“…Mohammadian and Zhang analyzed the effect of nanofluids on thermoelectric cooling performance with micro‐pin‐fin heat exchangers. Tan and Demirel investigated the performance and cooling efficiency of thermoelectric cooling modules on a server central processing unit. Zhang et al studied the thermal performance of a micro‐semiconductor laser with a thermoelectric cooling module.…”
Section: Introductionmentioning
confidence: 99%