2019
DOI: 10.20508/ijsmartgrid.v3i4.57.g64
|View full text |Cite
|
Sign up to set email alerts
|

Performance Analysis Of Grid-Connected CIGS PV Solar System And Comparison with PVsyst Simulation Program

Abstract: CIGS is the thin film technology (second generation) fabricated from Copper-Indium Gallium Selenide. This research displays the performance assessment of a 5kWp CIGS grid-connected PV Solar system. CIGS system installed at al-Mansour Company, Iraq-Baghdad (latitude 33.3 ° N, longitude 44.4 ° E and 41m above the sea level). The current paper presents the performance analysis of CIGS system (real system) and the comparison with PVsyst simulation program to find out how close are the CIGS system approaches perfec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 8 publications
0
2
0
Order By: Relevance
“…Where: HT and HR are the in-plane global insolation and reference irradiance , respectively. Equations ( 5) and ( 6) are substituted into equation ( 4) to obtain equation (7) as follows (Kasim et al,2019 ;Vikraman et al,2020). Where: PAC and ηActual represent, respectively, the actual power output and the actual efficiency.…”
Section: Performance Ratio (Pr)mentioning
confidence: 99%
“…Where: HT and HR are the in-plane global insolation and reference irradiance , respectively. Equations ( 5) and ( 6) are substituted into equation ( 4) to obtain equation (7) as follows (Kasim et al,2019 ;Vikraman et al,2020). Where: PAC and ηActual represent, respectively, the actual power output and the actual efficiency.…”
Section: Performance Ratio (Pr)mentioning
confidence: 99%
“…where ηref is the rated efficiency (15.2%), Am is the area of reference and improved PV modules (13.04 m 2 each), β is the temperature coefficient that equals -0.3%/°C, Tref is the reference modules' temperature (25°C), and Tm is the actual PV modules' temperature (Kasim et al, 2019). where PAC, Am and ηActual are the actual power, improved group area and actual efficiency, respectively.…”
Section: Performance Ratio (Pr)mentioning
confidence: 99%
“…Where:-η ref : rated efficiency (15.2%), A m : area of reference and enhanced groups (PV modules) (13.04 m 2 each), β: temperature coefficient (-0.3%/ O C), T ref : reference PV modules temperature (25 O C), and T m : actual PV modules temperature (Kasim et al, 2019).…”
Section: Performance Ratio (Pr)mentioning
confidence: 99%