Abstract:This research uses a swirl type MBG (MBG) with the gap variation between the air nozzle and the outlet of 1, 5 and10 mm. In this experiment, we used a tangential inlet of 25 mm and an outlet of 20 mm with a water flow rate of 20 – 70 l/min and an air flow rate range of 0.1 – 0.8 l/min, to determine the characteristics of MBG which include bubble distribution, pressure drop, hydraulic power, and efficiency. The probability of the diameter of the microbubble formed was in the range of 90 – 150 µm for all variati… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.