2012
DOI: 10.1093/annhyg/mes074
|View full text |Cite
|
Sign up to set email alerts
|

Penetration of Diesel Exhaust Particles Through Commercially Available Dust Half Masks

Abstract: Half masks are certified by the competent, national institutions--National Institute for Occupational Safety and Health (NIOSH) in the USA and the respective European national institutions applying common European regulations. However, certification testing is conducted with particles of NaCl, paraffin oil, or dioctyl phthalate (DOP) and at the constant flow rate, whereas particles commonly found in workplaces may differ in size, shape, and morphology from these particles. Therefore, the aim of this study was … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…A study of the filtration efficiency of masks mounted on a mannequin head with mask sealed to the head found penetration of diesel aerosol mass between 11% and 15% for FFP2 masks and 13%–24% for FFP3 masks. 11 These studies, however, did not account for inward leakage around the seal between the mask and face on humans.…”
Section: Introductionmentioning
confidence: 99%
“…A study of the filtration efficiency of masks mounted on a mannequin head with mask sealed to the head found penetration of diesel aerosol mass between 11% and 15% for FFP2 masks and 13%–24% for FFP3 masks. 11 These studies, however, did not account for inward leakage around the seal between the mask and face on humans.…”
Section: Introductionmentioning
confidence: 99%
“…N95 FFRs have been widely studied for filtration efficiency [ 11 , 12 ], face seal leakage [ 12 , 13 ], fit factors [ 14 , 15 ], and protection factors [ 6 , 10 ]. With respect to EN-specified FFP respirators, only the filtration efficiency was studied [ 16 ].…”
Section: Introductionmentioning
confidence: 99%
“…First, 400 ml of the suspension was dispersed using an ultrasonic homogenizer for 45 min in a cooling bath. Measurements were performed using fast aerosol particle emission spectrometry—FAPES (Grimm Aerosol Technic GmbH system, Germany) 21 . The exhaust gases were produced using a 5.5 kW EM 5500CX Honda (Japan) power generator for generating 230 V and 12 V alternating current.…”
Section: Methodsmentioning
confidence: 99%