2020
DOI: 10.29303/ipr.v3i1.37
|View full text |Cite
|
Sign up to set email alerts
|

PENENTUAN UKURAN BUTIR KRISTAL CuCr0,98Ni0,02O2 DENGAN MENGGUNAKAN X-RAY DIFRACTION (XRD) DAN SCANNING ELECTRON MICROSCOPE (SEM)

Abstract: Telah dilakukan pengukuran ukuran butir Kristal CuCr0,98Ni0,02O2 dengan menggunakan persamaan Scherer dan analisa langsung menggunakan Scanning Electron Microscope (SEM). Kristal CuCr0,98Ni0,02O2 disintesis dengan menggunakan metode solid state reaction.  Untuk dapat mendapatkan data menggunakan persamaan Scherer, sampel harus terlebih dahulu dikarakterisasi menggunakan X-Ray Difraction (XRD). Hasil penghitungan menggunakan persamaan Scherer menunjukkan ukuran butiran Kristal sebesar (0,113 ± 0,015) µm dengan … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0
3

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 4 publications
0
6
0
3
Order By: Relevance
“…This theory is known as Braggs Law. Thus, a fundamental statement for maximum interference in X-ray diffraction in the crystal is indicated by equation 1 [15].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…This theory is known as Braggs Law. Thus, a fundamental statement for maximum interference in X-ray diffraction in the crystal is indicated by equation 1 [15].…”
Section: Resultsmentioning
confidence: 99%
“…The GSAS method refers to the refinement method based on Rietveld analysis. This analysis refers to the refinement of the structure by matching the overall X-ray diffraction pattern to obtain microstructure data more accurate [15].…”
Section: P-issn : 2615 -1278 E-issn : 2614 -7904mentioning
confidence: 99%
“…After that, the Kebon Kongok TPA well water quality was measured using heated iron sand. The healthy water quality parameters measured included temperature, pH, and conductivity using the COM-600 Water Quality Tester [19]. The data obtained will be analyzed descriptively and presented in tables and diagrams.…”
Section: Methodsmentioning
confidence: 99%
“…Pengukuran dengan menggunakan PSA dilakukan untuk mengukur ukuran partikel sampel dan bukan mengukur ukuran butir karena pengukuran ukuran butir dapat dilakukan dengan menggunakan XRD [13]. Dengan mengetahui ukuran partikel maka dapat dihubungkan dengan banyaknya konsentrasi Fe yang terkandung dalam satu sampel.…”
Section: Hasil Dan Pembahasanunclassified
“…Semakin besarnya konsentrasi Fe akibat berkurangnya ukuran partikel disebabkan karena semakin kecil ukuran partikel maka akan semakin banyak batas butir di dalam sampel. Akibatnya konsentrasi Fe dalam sampel akan semakin besar seiring dengan berkurangnya ukuran partikel[13].…”
unclassified