PCA-Based Multi-Wavelength Photoplethysmography Algorithm for Cuffless Blood Pressure Measurement on Elderly Subjects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
17
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(26 citation statements)
references
References 14 publications
0
17
0
1
Order By: Relevance
“…There are two kinds of approaches for estimating BP based on PPG, using either the PPG signal only or PPG signal along with other signals (e.g., electrocardiogram) [11]. In [12][13][14][15], Pulse Transit Time (PTT)-based methods are carried out. PTT is the time interval between the R-peak of an electrocardiogram (ECG) and the point with maximum gradient on the rising edge of the PPG [16].…”
Section: Introductionmentioning
confidence: 99%
“…There are two kinds of approaches for estimating BP based on PPG, using either the PPG signal only or PPG signal along with other signals (e.g., electrocardiogram) [11]. In [12][13][14][15], Pulse Transit Time (PTT)-based methods are carried out. PTT is the time interval between the R-peak of an electrocardiogram (ECG) and the point with maximum gradient on the rising edge of the PPG [16].…”
Section: Introductionmentioning
confidence: 99%
“…From these principle components, Fourier transforms are used to extract features such as phase shift which indicates arteriolar PTT and HR with heart period and pulse decay time being computed separately. These features are used to compute mean blood pressure and pulse pressure which are then transformed into SBP and DBP estimates yielding errors of 1.44 ± 6.89mmHg for SBP and -1.00 ± 6.71mmHg for DBP [118].…”
Section: B Blood Pressurementioning
confidence: 99%
“…Utilizing multiple wavelengths for BP estimations showed improved error rates compared to single-wavelength estimations [73], [112], [118] especially when taking advantage of the differing interactions of wavelengths with skin and blood [118]. Methods that do not require an ECG device [73], [114], [118] have the advantage of not requiring multiple devices.…”
Section: B Blood Pressurementioning
confidence: 99%
“…Through principal component analysis, signal noise and motion artifacts were removed to obtain more satisfactory features, and the least squares method was adopted for blood pressure estimation. The mean absolute error and standard deviation for SBP and DBP were 5.51 ± 6.89 and 5.57 ± 6.71 mmHg, respectively [5]. Kyriacou et al applied a bidirectional recurrent neural network and attention mechanism to PPG signals, which were in turn used as signals in the Multiparameter Intelligent Monitoring in Intensive Care (MIMIC) II Databases to estimate blood pressure.…”
Section: Introductionmentioning
confidence: 99%