2011
DOI: 10.1016/j.jcrs.2010.10.058
|View full text |Cite
|
Sign up to set email alerts
|

Pathology of 157 human cadaver eyes with round-edged or modern square-edged silicone intraocular lenses: Analyses of capsule bag opacification

Abstract: No author has a financial or proprietary interest in any material or method mentioned.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
6
3

Relationship

3
6

Authors

Journals

citations
Cited by 18 publications
(13 citation statements)
references
References 27 publications
0
8
0
Order By: Relevance
“…1 In a subset of our series of pseudophakic cadaver eyes, eyes with 3-piece square-edged silicone IOLs, which are relatively new in the market, had significantly better PCO prevention results than eyes with 3-piece roundedged silicone IOLs. 20 After the introduction of 1-piece square-edged hydrophobic acrylic IOLs, studies comparing the PCO prevention of these IOLs with that of their 3-piece counterparts became available. 3,10-17 In a study by Sacu et al, 10 although eyes with 1-piece IOLs had slightly more PCO than eyes with 3-piece IOLs 1 year after implantation (PZ.002), the difference was no longer present after 2 years (PZ.3).…”
Section: Discussionmentioning
confidence: 99%
“…1 In a subset of our series of pseudophakic cadaver eyes, eyes with 3-piece square-edged silicone IOLs, which are relatively new in the market, had significantly better PCO prevention results than eyes with 3-piece roundedged silicone IOLs. 20 After the introduction of 1-piece square-edged hydrophobic acrylic IOLs, studies comparing the PCO prevention of these IOLs with that of their 3-piece counterparts became available. 3,10-17 In a study by Sacu et al, 10 although eyes with 1-piece IOLs had slightly more PCO than eyes with 3-piece IOLs 1 year after implantation (PZ.002), the difference was no longer present after 2 years (PZ.3).…”
Section: Discussionmentioning
confidence: 99%
“…Following technological advances, IOL design has been modified from round-edged to square-edged, and this has resulted in a reduction in the incidence of PCO (24) . However, studies suggest that square-edged IOLs should completely encompass the 360 degrees around the IOL optic in order to provide an effective barrier (25) .…”
Section: Discussionmentioning
confidence: 99%
“…This ultrasound provided imaging of the entire anterior segment of the eye via a noncontact, immersion technique. 19,20 …”
Section: Methodsmentioning
confidence: 99%