2014
DOI: 10.1016/j.radmeas.2014.08.006
|View full text |Cite
|
Sign up to set email alerts
|

Passive neutron area monitor with pairs of TLDs as neutron detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 18 publications
(7 citation statements)
references
References 27 publications
0
7
0
Order By: Relevance
“…The two TLD600 chips, enriched in 6 Li, can detect photons, charged particles and thermal neutrons (through the 6 Li(n, α) 3 H reaction), while the two TLD700 chips, where the 6 Li fraction has been depleted, respond identically to the TLD600 to gamma radiation and charged particles but are not as sensitive to thermal neutrons. This allows a separation of the neutron TL signal in a mixed radiation field by subtraction of the TLD700 signal from the one measured by the TLD600 [26][27][28]. The readout procedure of the TLD600H/700H crystals is described in the Supplementary Material.…”
Section: Gsi Ball: a Tld-based Neutron Dosimetermentioning
confidence: 99%
“…The two TLD600 chips, enriched in 6 Li, can detect photons, charged particles and thermal neutrons (through the 6 Li(n, α) 3 H reaction), while the two TLD700 chips, where the 6 Li fraction has been depleted, respond identically to the TLD600 to gamma radiation and charged particles but are not as sensitive to thermal neutrons. This allows a separation of the neutron TL signal in a mixed radiation field by subtraction of the TLD700 signal from the one measured by the TLD600 [26][27][28]. The readout procedure of the TLD600H/700H crystals is described in the Supplementary Material.…”
Section: Gsi Ball: a Tld-based Neutron Dosimetermentioning
confidence: 99%
“…In all Monte Carlo calculations, the number of histories was large enough to obtain uncertainties of less than 5%. For the calculations, the cross sections were taken from the ENDF/B VI library, where the S(α, β) treatment was included to take into account the thermalized neutron interactions (Vega Carrillo et al, 2014).…”
Section: Model Of Vehicle With Snms In Customsmentioning
confidence: 99%
“…Neutrons are transported through the polyethylene and reaching the sample. In order to take into account the transport of thermal neutron the S(α, β) treatment was included [Vega Carrillo et al (2014)]. In the model, the NaI(Tl) de tector was positioned at 13 cm from the sample, aligning the axial axis of the sample and detectors.…”
Section: Monte Carlo Calculationsmentioning
confidence: 99%