1992
DOI: 10.1021/ac00031a020
|View full text |Cite
|
Sign up to set email alerts
|

Parts-per-trillion determination of trihalomethanes in water by purge-and-trap gas chromatography with electron capture detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0

Year Published

1992
1992
2018
2018

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(17 citation statements)
references
References 12 publications
0
17
0
Order By: Relevance
“…Our results show that, in the case of bromoform at least, seawater chlorination far outweighs freshwater as an anthropogenic source of bromoform, and the small apparent atmospheric fluxes of the bromochloromethanes, which are believed to exceed emissions of bromoform in freshwater chlorination (Lepine and Archambault, 1992), also argues against a significant impact of freshwater chlorination on observed atmospheric THM concentrations.…”
Section: R Worton Et Al: Trends and Budgets Of Chloroform And Rementioning
confidence: 68%
“…Our results show that, in the case of bromoform at least, seawater chlorination far outweighs freshwater as an anthropogenic source of bromoform, and the small apparent atmospheric fluxes of the bromochloromethanes, which are believed to exceed emissions of bromoform in freshwater chlorination (Lepine and Archambault, 1992), also argues against a significant impact of freshwater chlorination on observed atmospheric THM concentrations.…”
Section: R Worton Et Al: Trends and Budgets Of Chloroform And Rementioning
confidence: 68%
“…Through this technique, the equilibrium state is not reached and, thus, more of the volatile dispersed in the matrix will pass into the headspace whose size results in increased sampling phase. As a consequence, the trapping stage of the analysis offers good sensitivity [43,115]. The proper combination of sorbent and temperature may permit collection and concentration of specific analytes while venting others.…”
Section: Sulfur Off-flavorsmentioning
confidence: 99%
“…The LODs for CF, DCBM, DBCM, and BF are 4.4, 1.5, 1.1, and 1.0 ng, respectively, and are listed in Table II. A second, and more accurate method, to analyze SAW responses to analyte exposures is to integrate the total area under each response peak. 9,10,[12][13][14]17 The integrated peak areas are plotted against the known injected analyte mass for each THM in Fig. 7b.…”
Section: Saw Performance Vs Npc Deposition Condition/mass Density-mentioning
confidence: 99%
“…8 Used in combination with purge and trap, GC-ECD can also achieve LODs <1 ppb for individual THM detection; however, all of these methods require some form of sample preparation. [9][10][11][12][13][14] Other detectors with GC have also been demonstrated, including microwave plasma emission, 15 thermal conductivity detection, 16 and atomic emission detection. 17 Arrays of surface acoustic wave (SAW) device sensors were successfully demonstrated to detect a large number of VOCs, including both chloroform and bromoform at 10 ppb concentrations in water, in combination with purge and trap methods, to develop a cost-effective alternative for on-site measurement of VOCs.…”
mentioning