Participation of a Pumped-Storage Electric Power Plant with Asynchronous Generator-Motors in Normalized Primary Frequency Regulation

Abstract: The main positive effects on the use of electrical machines with a variable rotation frequency are considered using the example of the Zagorsk pumped-storage power plant. It is shown that the possibility of regulating the electric active power, both in the generator and the pump modes, makes the power plant with asynchronous generator-motors more effective compared with units with synchronous generator-motors and enables it to provide services with normalized primary frequency regulation.Progress in the field … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 2 publications
(1 reference statement)
0
3
0
Order By: Relevance
“…e fitness function value of each particle is calculated, as shown in equations (18) and (19). Chemotaxis local search operation is carried out for global optimal particles and global worst particles of the current algebra according to a certain number of chemotactic steps and moving steps.…”
Section: Satisfy the End Conditionmentioning
confidence: 99%
See 1 more Smart Citation
“…e fitness function value of each particle is calculated, as shown in equations (18) and (19). Chemotaxis local search operation is carried out for global optimal particles and global worst particles of the current algebra according to a certain number of chemotactic steps and moving steps.…”
Section: Satisfy the End Conditionmentioning
confidence: 99%
“…However, when the PSURS is running at a low water head, it is easy to enter the "S" characteristic area, resulting in widespread range fluctuation and unstable operation of the unit's frequency. Especially when the unit participates in primary frequency regulation [18], the frequency disturbance will greatly increase the probability of wide range fluctuation of the PSU's frequency. e traditional PID controller cannot adjust the frequency fluctuation of PSU well.…”
Section: Introductionmentioning
confidence: 99%
“…At present, the rapid control mode conversion by the thermal power plant alone cannot fully meet the control requirements under the high power shortage. Therefore, it is proposed to make full use of the flexibility of the pumped storage units to adjust the resources [4,7].…”
Section: Introductionmentioning
confidence: 99%