2006
DOI: 10.1016/j.aca.2006.05.093
|View full text |Cite
|
Sign up to set email alerts
|

Partial least squares-based multivariate spectral calibration method for simultaneous determination of beta-carboline derivatives in Peganum harmala seed extracts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
50
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 65 publications
(54 citation statements)
references
References 30 publications
2
50
0
Order By: Relevance
“…According to the existing limited literature, the total alkaloid content of P. harmala seeds varies between 2% and 7% by dry weight [32,33] and the ratio of alkaloids in the plant may change at different stages of growth, whereas there are no data regarding the characterisation of the seed decoction. On the contrary, Ayahuasca beverages of the south western Amazon basin were extensively characterized by Rivier and Lindgren [18] that determined the presence of harmine in the range 0.07-0.19 mg/mL, THH in the range 0.015-0.09 mg/mL and harmaline in the range 0.003-0.016 ng/mL.…”
Section: Infusionmentioning
confidence: 99%
“…According to the existing limited literature, the total alkaloid content of P. harmala seeds varies between 2% and 7% by dry weight [32,33] and the ratio of alkaloids in the plant may change at different stages of growth, whereas there are no data regarding the characterisation of the seed decoction. On the contrary, Ayahuasca beverages of the south western Amazon basin were extensively characterized by Rivier and Lindgren [18] that determined the presence of harmine in the range 0.07-0.19 mg/mL, THH in the range 0.015-0.09 mg/mL and harmaline in the range 0.003-0.016 ng/mL.…”
Section: Infusionmentioning
confidence: 99%
“…PLS is a linear regression tool based on full-spectrum (Hemmateenejad, Abbaspour, Maghami, Miri, & Panjehshahin, 2006). And PLS has been reported in analysis of numerous cases (Cozzolino, et al, 2004;SzydlowskaCzerniak, 2007).…”
Section: Introductionmentioning
confidence: 98%
“…When compared to the results achieved using MECK, it has been demonstrated that SSRTP can be potentially used for such analytical application. SSRTP method is simple and selective, eliminating the need for neither powerful separation methods (HPLC 20 , for instance) to isolate the analyte from the tested potentially interferent substances nor multivariate approaches 24 for the determination of harmane in mixtures. …”
Section: Discussionmentioning
confidence: 99%