1995
DOI: 10.1049/ip-smt:19951643
|View full text |Cite
|
Sign up to set email alerts
|

Partial discharge signal generation transmission and acquisition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

1995
1995
2012
2012

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…Such presentations are used to present results of multi-dimensional PDS, of which several variants have been proposed, e.g., [94-971. In particular, PDS of a combination of amplitude and phase distributions (sometimes called PRPDA where P R stands for 'phase resolved') has been developed independently or in crossfertilized ways by several workers. For a recent review of applications and metrological considerations, see [98].…”
Section: Multi-dimensional Pdsmentioning
confidence: 99%
See 1 more Smart Citation
“…Such presentations are used to present results of multi-dimensional PDS, of which several variants have been proposed, e.g., [94-971. In particular, PDS of a combination of amplitude and phase distributions (sometimes called PRPDA where P R stands for 'phase resolved') has been developed independently or in crossfertilized ways by several workers. For a recent review of applications and metrological considerations, see [98].…”
Section: Multi-dimensional Pdsmentioning
confidence: 99%
“…With this kind of resource available it is natural, not only to improve data handling and final presentation, but to extract whatever information is hidden in the data mass to improve the evaluation of the recorded pulse spectra. Efforts in this direction were stimulated by the expectation that successful approaches might be useful in the development of diagnostic Expert systems [76,98] or other variants of AI.…”
Section: Transforms For Pds Pattern Recognitionmentioning
confidence: 99%
“…The introduction of the phase-resolved partial discharge pattern (φ-q-n pattern) in the early 1990ies greatly improved the interpretation and analysis of partial discharge activity [3,4,5]. Especially, activities with low repetition rates of the partial discharge event unveil their statistical properties only after a certain acquisition time.…”
Section: Partial Discharge Patternmentioning
confidence: 99%
“…Generally, the φ-q-n pattern is independent of the used acquisition frequency or band [3,15], as both the phase position and the amplitude relation between different partial discharge pulses stay consistent and remain relevant after processing procedures, such as mixing or level detection. However, when leaving the low frequency range of the IEC60270, the calibration becomes increasingly location and frequency dependent [14,15].…”
Section: Partial Discharge Patternmentioning
confidence: 99%
“…The same effect, but with a negative reflection factor is found, when the signal wants to enter the slot section. Field measurements on various types of generators with a spectrum analyzer proved a strong attenuation for frequencies above of 40MHz [4].…”
Section: (2)mentioning
confidence: 96%