2016 IEEE International Symposium on Electromagnetic Compatibility (EMC) 2016
DOI: 10.1109/isemc.2016.7571696
|View full text |Cite
|
Sign up to set email alerts
|

Parameter for near end crosstalk prediction in twisted pair cables

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…Although the electronic equipment used in this study was manufactured in accordance with EMC directive, it does not mean that overall radiation from telecommunications network in user premises meets the radiation limits defined by the international authorities. The reason for this is that the telecommunications network in addition to electronic equipment also consists of existing copper telecommunications cables that are not usually designed to transmit data at frequencies used by G.fast2 technology, resulting in increased radiation when the signal passes through it [28]. Therefore, in order to analyse the influence of cable construction on the measured level of E ‐field radiation, the measurement is performed for different types of telecommunication cables.…”
Section: Measurement Setupmentioning
confidence: 99%
“…Although the electronic equipment used in this study was manufactured in accordance with EMC directive, it does not mean that overall radiation from telecommunications network in user premises meets the radiation limits defined by the international authorities. The reason for this is that the telecommunications network in addition to electronic equipment also consists of existing copper telecommunications cables that are not usually designed to transmit data at frequencies used by G.fast2 technology, resulting in increased radiation when the signal passes through it [28]. Therefore, in order to analyse the influence of cable construction on the measured level of E ‐field radiation, the measurement is performed for different types of telecommunication cables.…”
Section: Measurement Setupmentioning
confidence: 99%
“…(57) Because the choice of constellation is shared by all pairs on the same tone for the LR-ZFP and the LR-THP, we emphasize this fact by neglecting the pair index j for the terms ρ t and P t in Eq. (56) and (57). In terms of the transmitter's power transfer characteristics between the input u u u t and the output x x x t , Eq.…”
Section: ) Inner Spectrum Balancing Policymentioning
confidence: 99%