2019
DOI: 10.1016/j.bios.2019.111686
|View full text |Cite
|
Sign up to set email alerts
|

Paper-based 3D culture device integrated with electrochemical sensor for the on-line cell viability evaluation of amyloid-beta peptide induced damage in PC12 cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
16
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(16 citation statements)
references
References 23 publications
0
16
0
Order By: Relevance
“…Paper was also used as a medium for cell culture. In this case, the SPE platform allowed the on-line evaluation of cell viability by monitoring dopamine release from cell damage models [109]. Alternatively, the paper was also combined with a SPE card for sampling, as in the tear sampling system developed by Honikel et al using Whatman No 41 ashless filter paper [90].…”
Section: Spe Cards Combined With Paper Elementsmentioning
confidence: 99%
“…Paper was also used as a medium for cell culture. In this case, the SPE platform allowed the on-line evaluation of cell viability by monitoring dopamine release from cell damage models [109]. Alternatively, the paper was also combined with a SPE card for sampling, as in the tear sampling system developed by Honikel et al using Whatman No 41 ashless filter paper [90].…”
Section: Spe Cards Combined With Paper Elementsmentioning
confidence: 99%
“…[25][26][27] The core peptide residues of Ab hydrophilic peptides are 17 to 21 and 30 to 42 which have been connected to the aggregation methods, so that 17 to 21 residues inhibit similar degree of the hydrophobic environments yet have a very less ratio to adopt the b-sheet confirmations. [28][29][30] From the recent reports, Shyam et al described the linear polyethylene glycol polymer-based micelles nanocomposition frame of BACE1 in the brain via infusing the nanocomposition in mouse lateral ventricle. 31 However, the nanocomposition meets various clinical strategies for the translation, for example, invasive administration protocols or risk of the immune or inflammatory actions.…”
Section: Introductionmentioning
confidence: 99%
“… 25 - 27 The core peptide residues of Aβ hydrophilic peptides are 17 to 21 and 30 to 42 which have been connected to the aggregation methods, so that 17 to 21 residues inhibit similar degree of the hydrophobic environments yet have a very less ratio to adopt the β-sheet confirmations. 28 - 30 …”
Section: Introductionmentioning
confidence: 99%
“…A particular challenge exists for pH measurements of airway epithelial cells grown under air-liquid interface culture conditions on Transwell inserts as there is a small growth surface area contributing to a low volume and depth of ASL. Since the measurement of pH in a cell culture system has been recognized as a useful tool to study different aspects of the cells' biology, various pH sensors have been developed [27][28][29][30][31][32] . Several techniques, such as optical sensing methods [33][34][35] , ion-sensitive field-effect transistor-based sensors, or electrochemical pH sensing materials 36 , have been investigated to monitor pH in a biological application.…”
mentioning
confidence: 99%