Integrated Optics: Devices, Materials, and Technologies XX 2016
DOI: 10.1117/12.2212646
|View full text |Cite
|
Sign up to set email alerts
|

Packaged integrated opto-fluidic solution for harmful fluid analysis

Abstract: Advances in nuclear fuel reprocessing have led to a surging need for novel chemical analysis tools. In this paper, we present a packaged lab-on-chip approach with co-integration of optical and micro-fluidic functions on a glass substrate as a solution. A chip was built and packaged to obtain light/fluid interaction in order for the entire device to make spectral measurements using the photo spectroscopy absorption principle. The interaction between the analyte solution and light takes place at the boundary bet… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 22 publications
0
3
0
Order By: Relevance
“…A disadvantage of the latter methods is the curing/annealing temperature, which is around 250°C for an optimal strong bond. The curing/annealing can be performed at lower temperatures (∼150°C), leading to longer process times (>10 hours) and often to weaker bonds [25]. The specifications of the mentioned adhesives are shown in Table 1.…”
Section: Adhesivesmentioning
confidence: 99%
See 1 more Smart Citation
“…A disadvantage of the latter methods is the curing/annealing temperature, which is around 250°C for an optimal strong bond. The curing/annealing can be performed at lower temperatures (∼150°C), leading to longer process times (>10 hours) and often to weaker bonds [25]. The specifications of the mentioned adhesives are shown in Table 1.…”
Section: Adhesivesmentioning
confidence: 99%
“…This change entailed an increase of the annealing time to 72 hours in order to provide enough energy to create the covalent bonds. A previous study [25] showed that, with such a process, a surface energy, γ, greater than 1 J/m 2 is achieved, which allows the bond to withstand standard mechanical processes such as dicing and polishing. After the molecular bonding, both surfaces are crack free, as shown in Fig.…”
Section: Direct Bondingmentioning
confidence: 99%
“…The substrate is then plunged into a molten salt bath in order to proceed to the ion exchange. On the other hand, the fluidic wafer is obtained with a wet HF etching process, described in detail in previous work 7 . The microfluidic channel allows interaction of 2 cm, with a channel depth of 150 μm.…”
Section: Sensor Fabrication and Characterizationmentioning
confidence: 99%