1972
DOI: 10.1016/0002-9149(72)90128-2
|View full text |Cite
|
Sign up to set email alerts
|

P wave synchronous pacing using anchored atrial electrode implanted without thoracotomy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
4
0

Year Published

1975
1975
2003
2003

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(4 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…Studies on long‐term temporary atrial pacing are scarce. Initial series reported limited success with a relatively high dislocation rate and high threshold values 10–13 . Some investigators have suggested specific lead designs to obtain a stable and reliable atrial position.…”
Section: Discussionmentioning
confidence: 99%
“…Studies on long‐term temporary atrial pacing are scarce. Initial series reported limited success with a relatively high dislocation rate and high threshold values 10–13 . Some investigators have suggested specific lead designs to obtain a stable and reliable atrial position.…”
Section: Discussionmentioning
confidence: 99%
“…Electrode dislodgement has been a troublesome problem, but ongoing modification of the electrode configuration and further clinical experience have substantiated the potential usefulness of these right atrial approaches.12 14 Other pervenous methods using atrioventricular electrodes", and electrodes with barbs and hooks for atrial fixation have had only limited trials. 16 Eleven malpacing events were observed in the 50 reported patients during 1531 atrial pacing months for an average event rate of 0.72% per paced month. In the seven patients with either electrode dislodgement out of the coronary vein or the development of a high threshold, the initial atrial pacing threshold averaged 4.4 ± 2.8 ma, a value almost twice that of our entire series.…”
Section: Discussionmentioning
confidence: 99%
“…Apart from the mediastinal atrial electrode (Carlens et al, 1965;Lagergren et al, 1966a, b;Larsson et al, 1969;Larsson, 1970;Kleinert and Nahrstedt, 1974) there are two main approaches for introducing the electrode: implantation via thoracotomy Nathan et al, 1964;Center and Nathan, 1966;Silverman et al, 1968;Nusbaum and Levit, 1970;Cleveland et al, 1972;Mills and Ochsner, 1973;Perryman and Sealy, 1973) and transvenous techniques (Rodewald et al, 1964; Detector electrode for atrial triggered cardiac pacing Hunt and Sloman, 1968;Kastor et al, 1969;Moss et al, 1969;Kramer and Moss, 1970a, b;Kitamura et al, 1971;Vogel et al, 1971;Rosenkranz and Schaldach, 1971;Bleifeld et al, 1971;Smyth et al, 1971a, b;Porstmann et al, 1972;Zucker et al, 1973;Cappelen and Hall, 1974;Moss et al, 1974;Obel and Scott Millar, 1975;Rubenfire, 1975). Reviews of different methods have been given by Dodinot et al (1969), Sowton (1969), Benchimol and Goldstein (1969), Nathan et al (1971), DeSanctis (1971, and Furman (1973).…”
Section: Discussionmentioning
confidence: 99%