2019
DOI: 10.1016/j.electacta.2019.06.052
|View full text |Cite
|
Sign up to set email alerts
|

Oxidation potentials of guanine, guanosine and guanosine-5′-monophosphate: Theory and experiment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 61 publications
1
10
0
Order By: Relevance
“…5, the oxidation peak current of [Ru(bpy) 2 dpp] 2+ →[Ru(bpy) 2 dpp] 3+ + e − remained constant with pH. On the contrary, the oxidation peak current of 5ʹ-GMP decreased significantly with increasing pH, which was consistent with studies related to the greater susceptibility of 5ʹ-GMP to oxidation under acidic conditions [31]. The oxidation peak current of 5ʹ-GMP was maximum at pH 3, which is consistent with the choline monolayer carrier and gold nanocavity functionalized carbon nanotube sensing interface (pH 4) and carboxylated multi-walled carbon nanotubes/AuNPs modified glassy carbon electrode (pH 3) in comparison [32,33].…”
Section: Optimization Experiments Optimization Analysis Of the Ph Of ...supporting
confidence: 87%
“…5, the oxidation peak current of [Ru(bpy) 2 dpp] 2+ →[Ru(bpy) 2 dpp] 3+ + e − remained constant with pH. On the contrary, the oxidation peak current of 5ʹ-GMP decreased significantly with increasing pH, which was consistent with studies related to the greater susceptibility of 5ʹ-GMP to oxidation under acidic conditions [31]. The oxidation peak current of 5ʹ-GMP was maximum at pH 3, which is consistent with the choline monolayer carrier and gold nanocavity functionalized carbon nanotube sensing interface (pH 4) and carboxylated multi-walled carbon nanotubes/AuNPs modified glassy carbon electrode (pH 3) in comparison [32,33].…”
Section: Optimization Experiments Optimization Analysis Of the Ph Of ...supporting
confidence: 87%
“…The recorded CV curve showed the characteristic oxidation peak of MB at ∼−0.1/+0.1 V vs. the Ag/AgCl reference electrode, as shown in Figure 4a, as compared to the bare sensor. We additionally considered if the charge transfer arising from the oxidation/reduction of oligo bases, such as guanosine, 49 would interfere with the MB peak current. The response of two identical sensor strips functionalized with the same oligo sequence was tested with and without the MB functionality at its 3′ terminal.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…Guanosine, a purine nucleoside, is an important metabolite with a nucleobase guanine that is attached to an anomeric carbon of ribofuranose (a ribose) via a β‐N 9 ‐glycosidic bond. It is one of the important neuromodulators and neouroprotectors in the brain that reduces the effects of neurological events such as traumatic injuries and strokes . It triggers several important activities.…”
Section: Introductionmentioning
confidence: 99%
“…When it comes to guanosine monitoring and detection, there have been very few attempts using electrochemical techniques. Guanosine is an electroactive compound . For this reason, electrochemical approach can serve certain and significant benefits upon other techniques.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation