2016
DOI: 10.1002/jctb.5033
|View full text |Cite
|
Sign up to set email alerts
|

Oxidation of N-nitrosodimethylamine in a heterogeneous nanoscale zero-valent iron/H2O2Fenton-like system: influencing factors and degradation pathway

Abstract: BACKGROUND: N-nitrosodimethylamine (NDMA) is an emerging disinfection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 50 publications
(105 reference statements)
2
5
0
Order By: Relevance
“…Similar results were reported by other researchers. 4548 This is because anions such as nitrate, sulfate, chloride, phosphate, and bicarbonate have been reported to scavenge • OH to form less active ionic radicals (such as NO 3 • , SO 4 •– , Cl • , PO 4 •2– , and HCO 3 • /CO 3 •– ) than • OH or • O 2 – . 4548…”
Section: Resultsmentioning
confidence: 99%
“…Similar results were reported by other researchers. 4548 This is because anions such as nitrate, sulfate, chloride, phosphate, and bicarbonate have been reported to scavenge • OH to form less active ionic radicals (such as NO 3 • , SO 4 •– , Cl • , PO 4 •2– , and HCO 3 • /CO 3 •– ) than • OH or • O 2 – . 4548…”
Section: Resultsmentioning
confidence: 99%
“…With Cl − concentration increasing from 0 to 5 mmol L −1 , the removal efficiency of OTC decreased from 93.3% to 43.3% in 40 min; and the degradation rate constant decreased from 0.067 to 0.014 min −1 correspondingly. A previous study 6 indicated that Cl − would compete with • OH in the nanoscale zero‐valent iron/H 2 O 2 Fenton‐like system for the removal of NDMA. In the visible‐light‐driven SCN catalytic system, • OH is one type of ROS for the degradation of OTC.…”
Section: Resultsmentioning
confidence: 99%
“…Other instrumental parameters were set as follows: capillary voltage of 3.0 kV, cone voltage of 40 V, desolvation gas flow of 990 L h –1 , cone gas flow of 50 L h –1 , source temperature of 100 °C and desolvation temperature of 300 °C. In addition to the degradation intermediates detected using UPLC‐ESI‐MS, DMA as an important degradation intermediate was also determined during the degradation period, and it was quantified using HPLC in accordance with our previous studies 6, 29, 30 …”
Section: Methodsmentioning
confidence: 91%