2013
DOI: 10.1016/j.enbuild.2013.02.015
|View full text |Cite
|
Sign up to set email alerts
|

Overvoltage prevention in LV smart grid using customer resources coordination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 41 publications
(16 citation statements)
references
References 23 publications
0
16
0
Order By: Relevance
“…It has been found in literature that power quality issues can occur at distribution, generation, and transmission side in all RES integrated grids . Intermittent characteristics of solar PV appears due to rapid alterations between sunshine and clouds which cause voltage fluctuation and unbalance, whereas, varying wind speed affects the wind power generation . Voltage flickers caused by the impact of machines vary inversely with the fault level at point of common coupling which impose significant impact on grid.…”
Section: Limitations and Constraints Of Renewable Integrationmentioning
confidence: 99%
See 1 more Smart Citation
“…It has been found in literature that power quality issues can occur at distribution, generation, and transmission side in all RES integrated grids . Intermittent characteristics of solar PV appears due to rapid alterations between sunshine and clouds which cause voltage fluctuation and unbalance, whereas, varying wind speed affects the wind power generation . Voltage flickers caused by the impact of machines vary inversely with the fault level at point of common coupling which impose significant impact on grid.…”
Section: Limitations and Constraints Of Renewable Integrationmentioning
confidence: 99%
“…55 Intermittent characteristics of solar PV appears due to rapid alterations between sunshine and clouds which cause voltage fluctuation and unbalance, whereas, varying wind speed affects the wind power generation. 87 Voltage flickers caused by the impact of machines vary inversely with the fault level at point of common coupling which impose significant impact on grid. Voltage fluctuation affects the lifetime of sensitive electronics and electrical equipment.…”
Section: Limitations and Constraints Of Renewable Integrationmentioning
confidence: 99%
“…As listed in literature, using resources in distribution network such as PVs active and reactive power [9], controllable loads [10,11], DSTATCOMs [12] and energy storage units [13] has promising features to avoid such issues.…”
Section: Introductionmentioning
confidence: 99%
“…), storage units can be added beside PV units and the reference value for storage active power ( mined as equation(11).…”
mentioning
confidence: 99%
“…This strategy is usually used to deal with voltage fluctuation in distribution network. References [14][15][16] use reactive power control in distribution network to deal with voltage rise.…”
Section: Source Reactive Powermentioning