2019
DOI: 10.1016/j.rser.2018.09.047
|View full text |Cite
|
Sign up to set email alerts
|

Overview of emerging subsynchronous oscillations in practical wind power systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
44
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 137 publications
(47 citation statements)
references
References 75 publications
1
44
0
Order By: Relevance
“…Power system stability problems are concerned with the generation of SSOs . This phenomenon in conventional plants is originated due to subsynchronous interaction of mechanical shaft of turbo‐generator with active control of transmission lines or compensated transmission lines . Extensive literature has been studied and documented for mitigation of SSOs in conventional power systems .…”
Section: Limitations and Constraints Of Renewable Integrationmentioning
confidence: 99%
See 1 more Smart Citation
“…Power system stability problems are concerned with the generation of SSOs . This phenomenon in conventional plants is originated due to subsynchronous interaction of mechanical shaft of turbo‐generator with active control of transmission lines or compensated transmission lines . Extensive literature has been studied and documented for mitigation of SSOs in conventional power systems .…”
Section: Limitations and Constraints Of Renewable Integrationmentioning
confidence: 99%
“…91,92 This phenomenon in conventional plants is originated due to subsynchronous interaction of mechanical shaft of turbogenerator with active control of transmission lines or compensated transmission lines. 93 Extensive literature has been studied and documented for mitigation of SSOs in conventional power systems. 94 However, in wind powerconnected grids, SSOs are found because of induction generator with a series-compensated transmission line.…”
Section: Limitations and Constraints Of Renewable Integrationmentioning
confidence: 99%
“…Hence, only detailed analysis of mode 4(5) is presented, although all other modes were studied. Also only 2nd order modal interaction coefficients (h2 4,5 kl z 0 k z 0 l ) were examined in detail for both NF-35,000 and NF-9310 models.…”
Section: Analysis Of Casementioning
confidence: 99%
“…Moreover, power electronic (PE) converters interfacing these new technologies to the grid also raise some concerns. For example, the PE converters could form a virtual capacitance, which could interact with the AC grid to trigger an unstable subsynchronous oscillation in a relatively weak system [4]. Each type of RE or EV creates challenges ranging from over-voltage, under-voltage, harmonics, stability issues, and many more.…”
Section: Introductionmentioning
confidence: 99%
“…Today and in the future, the sharing of renewable energy sources of electricity generation is show a continuous significant increase the role of renewable sources in world. SO far various studies have been done on the application of FACTS devices in the energy system [29,30]. The use of the UPFC in order to improve the stability margin and also to damp out the power fluctuations in a combined wind and wave energy production system connected to bulk power network has been shown in [31].…”
mentioning
confidence: 99%