2023
DOI: 10.1016/j.ejmp.2023.102529
|View full text |Cite
|
Sign up to set email alerts
|

Out-of-field measurements and simulations of a proton pencil beam in a wide range of dose rates using a Timepix3 detector: Dose rate, flux and LET

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 48 publications
0
9
0
Order By: Relevance
“…Compared to the rigid version of the MiniPIX Timepix3 (TPX3) detector (Gohl et al 2022, Granja et al 2022, the customised Flex version has a unique design: the sensor was moved 5 cm away from the electronic components using a flexible printed circuit board (PCB) (Oancea et al 2023). Moreover, to minimize the radiation field perturbation, all metal parts were replaced by plastic and the chip-sensor assembly was placed on an extruded graphite support chiller, see figure 1(a).…”
Section: Instrumentation and Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…Compared to the rigid version of the MiniPIX Timepix3 (TPX3) detector (Gohl et al 2022, Granja et al 2022, the customised Flex version has a unique design: the sensor was moved 5 cm away from the electronic components using a flexible printed circuit board (PCB) (Oancea et al 2023). Moreover, to minimize the radiation field perturbation, all metal parts were replaced by plastic and the chip-sensor assembly was placed on an extruded graphite support chiller, see figure 1(a).…”
Section: Instrumentation and Measurementsmentioning
confidence: 99%
“…The detector electronic's component was built into the 3D printed plastic holder, which was designed to facilitate the immersion of the detector under water. The plastic holder was designed to be compatible with the positioning system of the water tank (Oancea et al 2023) to ease the final assembly (figure 1(b)). The holder was placed into a silicon medicinal cover (thickness of 65 μm) for waterproofing purposes.…”
Section: Instrumentation and Measurementsmentioning
confidence: 99%
“…These and further steps of data processing are made using the integrated data processing engine (DPE) [20]. Developed by ADVACAM, the DPE tool performs data clustering, applies per-pixel energy calibration, and calculates for each particle track morphological and spectral parameters, including cluster size, length, roundness, deposited energy and LET [4,21,22].…”
Section: Data Processingmentioning
confidence: 99%
“…Timepix detectors are used in a broad range of applications [1,2] ranging from medical imaging, material research to space radiation monitoring [3][4][5][6][7]. These environments are characterised by high-intensity radiation fields that degrade and damage the detectors exposed for an extended period of time.…”
Section: Introductionmentioning
confidence: 99%
“…Similarly, from a dosimetric point of view, L Δ,,D has been considered as a better parameter to describe the response of different dosimeters [7][8] . In radiotherapy with protons, research has been made to investigate not only the absorbed dose outside of the eld [9][10] but also the L Δ,,D distribution in organs at risk close the tumour volume [11][12] .…”
Section: Introductionmentioning
confidence: 99%