1993
DOI: 10.1016/s0749-8063(05)80506-7
|View full text |Cite
|
Sign up to set email alerts
|

Osteochondritis dissecans: A historical review and its treatment with cannulated screws

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
56
0
4

Year Published

1997
1997
2018
2018

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 104 publications
(65 citation statements)
references
References 29 publications
0
56
0
4
Order By: Relevance
“…It is unlikely that a single implant is ideal in all circumstances. Based on our observations and outcomes reported from clinical studies, 3,[8][9][10]12 an osteochondral fragment seated within its bed might require the least stiff fixation device. However, in the context of a mismatch between the defect site and its corresponding fragment, OCD might be more amenable to rigid fixation with a compression screw system.…”
Section: Discussionmentioning
confidence: 79%
See 2 more Smart Citations
“…It is unlikely that a single implant is ideal in all circumstances. Based on our observations and outcomes reported from clinical studies, 3,[8][9][10]12 an osteochondral fragment seated within its bed might require the least stiff fixation device. However, in the context of a mismatch between the defect site and its corresponding fragment, OCD might be more amenable to rigid fixation with a compression screw system.…”
Section: Discussionmentioning
confidence: 79%
“…3,[8][9][10][11] While no defined mechanism of failure following fixation has been identified, we suspect that subjecting the repair site to loads in shear is a contributing factor. Our results revealed all methods of internal fixation performed significantly better than the control, with the construct using the longest AO screw and threaded washer providing the greatest stability.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The majority of patients undergoing this technique report good to excellent results without major complications [60][61][62]. The use of cannulated screws has also been described with successful results; however, the major drawback is the concern for increased articular cartilage morbidity due to screw prominence on the articular surface [63,64]. Cannulated headless compression screws have now been developed as an alternative, which theoretically combines the advantages of both techniques [65].…”
Section: Lesion Fixationmentioning
confidence: 99%
“…Ist das Dissekat bereits erheblich gelockert, jedoch noch vital und unfragmentiert, kann eine Verschraubung unter arthroskopischer Kontrolle erwogen werden. Kanu È lierte Schrauben sind zu bevorzugen, die Schraubenko È pfe mu È ssen versenkt werden und die Implantate sollten baldmo È glichst wieder entfernt werden [17]. Die Verwendung von Doppelgewindeschrauben ist fu È r diese Indikation ebenfalls beschrieben worden [46,54].…”
Section: Osteochondrosis Dissecansunclassified