2017
DOI: 10.1021/acs.jpcb.6b11936
|View full text |Cite
|
Sign up to set email alerts
|

Organic-Gelatin-Free Nanocomposite Fricke Gel Dosimeter

Abstract: We report a nanocomposite Fricke gel (NC-FG) dosimeter prepared using only Fe and nanoclay in water, without any organic gelling agents. This dosimeter gels due to its thixotropic properties and exhibits linear energy transfer (LET)-independent radiological properties under carbon ion beam irradiation. The radiation sensitivity of this dosimeter was 1.8 [s kGy], which is three times higher than that reported previously (0.6 [s kGy]) for a similar dosimeter containing gelatin. The Fe yield was determined to be … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
20
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 34 publications
(23 citation statements)
references
References 43 publications
1
20
0
Order By: Relevance
“…Maeyama et al [ 32 ], developed a novel nanocomposite Fricke gel (NC-FG) with nano-sized clay particles and degassing operation to improve LET dependence. The carbon beam depth dose distribution was found to be in good agreement with the ionization chamber measurements [ 32 , 33 , 34 ].…”
Section: Introductionsupporting
confidence: 57%
See 2 more Smart Citations
“…Maeyama et al [ 32 ], developed a novel nanocomposite Fricke gel (NC-FG) with nano-sized clay particles and degassing operation to improve LET dependence. The carbon beam depth dose distribution was found to be in good agreement with the ionization chamber measurements [ 32 , 33 , 34 ].…”
Section: Introductionsupporting
confidence: 57%
“…However, before and after the Bragg peak, the R 1 values were higher and lower, respectively, than the IC measurement values. This phenomenon was not shown in our previous MRI measurement conditions [ 34 ], and thus, it was considered to represent a truncation artifact due to its sharp edges [ 63 ]. Truncation artifacts occur when the MR signal obtained by finite sampling is Fourier transformed to reconstruct an image [ 64 , 65 ].…”
Section: Resultsmentioning
confidence: 92%
See 1 more Smart Citation
“…It should be noted that HD-V2 Gafchromic™ films have a different structure from the other Gafchromic™ films as they feature a 12 µm thin active layer on a 97 µm polyester substrate. The LET dependence is common to other types of dosimeters; however, recently developed nanocomposite Fricke gel dosimeters have shown to have no dependence on the LET in a wide LET range [116,117].…”
Section: Radiochromic Films Response To Relevant Physical Quantitiesmentioning
confidence: 99%
“…As a typical gel dosimeter, 7 there are Fricke gel [8][9][10][11] and polymer gel [12][13][14][15] dosimeters, and many radiosensitizers 2, [16][17][18][19][20] have been investigated because improving sensitivity is an issue, up to now. On the other hand, there are not many reports in the gel dosimeters utilizing uorometry using radiosensitizers, although there are several type of radio-uorogenic gels.…”
Section: Introductionmentioning
confidence: 99%