Organ and effective doses from verification techniques in image-guided radiotherapy

Abstract: The purpose of this work was an evaluation of organ doses and effective doses from three verification techniques in Image-Guided Radiotherapy: from kilovoltage (kV) cone beam computed tomography (CBCT) scans, from two orthogonal kV images and from two orthogonal megavoltage (MV) images for two different treatment sites: pelvis and head and neck (H&N). For comparison reasons, organ doses and effective doses from prostate and H&N radiotherapy were also evaluated. Measurements of organ doses were performed in a m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
2

Year Published

2013
2013
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 6 publications
0
8
0
2
Order By: Relevance
“…The influence of new scan protocols that were released with new software versions (i.e. upgraded versions) on image quality and patient doses have been investigated in several studies (Palm et al, 2010, Ding et al, 2010, Dufek et al, 2011, Ding and Munro, 2013. These studies showed that the default scan protocols implemented in new versions usually played a role in improving the image quality and minimizing organ and effective doses.…”
Section: Influence Of the Scan Parametersmentioning
confidence: 99%
“…The influence of new scan protocols that were released with new software versions (i.e. upgraded versions) on image quality and patient doses have been investigated in several studies (Palm et al, 2010, Ding et al, 2010, Dufek et al, 2011, Ding and Munro, 2013. These studies showed that the default scan protocols implemented in new versions usually played a role in improving the image quality and minimizing organ and effective doses.…”
Section: Influence Of the Scan Parametersmentioning
confidence: 99%
“…Several studies reported on the effective doses from kilovoltage CBCT [6,31,33,34,39,43,90]. In all these cases, the absorbed dose was measured in an anthropomorphic phantom and converted to effective dose using the tissue weighting factors obtained from International Commission on Radiological Protection (ICRP) reports 60 and 103 [91,92].…”
Section: Estimation Of Effective Dose From Cbct Imagingmentioning
confidence: 99%
“…W tabeli 1 przedstawiono podsumowanie wybranych monografii naukowych na temat dawek pochodzących z obrazowania metodą kV-CBCT [14][15][16][17][18][19][20][21][22][23][24][25][26][27]. Dodatkowo w tabeli 2 wyszczególniono otrzymane wyniki dla poszczególnych narządów, które znaleźć można w publikacji M.W.…”
Section: Szacowane Dawki Dla Wybranych Protokołów Obrazowaniaunclassified
“…Dawki pochodzące z obrazowania metodą kV-CBCT raportowane w publikacjach naukowych, w których wykorzystano fantom antropomorficzny. Opracowano na podstawie[14][15][16][17][18][19][20][21][22][23][24][25][26][27].Kinga Graczyk , Marta Kruszyna-Mochalska / Zeszyty Naukowe WCO, Letters in Oncology Science 2022;19(1):97-104 100…”
unclassified