Orbit image analysis machine learning software can be used for the histological quantification of acute ischemic stroke blood clots

Abstract: Our aim was to assess the utility of a novel machine learning software (Orbit Image Analysis) in the histological quantification of acute ischemic stroke (AIS) clots. We analyzed 50 AIS blood clots retrieved using mechanical thrombectomy procedures. Following H&E staining, quantification of clot components was performed by two different methods: a pathologist using a reference standard method (Adobe Photoshop CC) and an experienced researcher using Orbit Image Analysis. Following quantification, the clots were… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
53
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1
1

Relationship

3
6

Authors

Journals

citations
Cited by 62 publications
(53 citation statements)
references
References 27 publications
0
53
0
Order By: Relevance
“…6 Recent studies have shown large-scale heterogeneity in the composition of retrieved clots, in terms of the percentage of fibrin/platelet aggregates (FP), red blood cell (RBC), and white blood cells (WBC). 7 Differences in clot composition have been associated with stroke etiology and MT treatment outcomes. In several studies, FP-rich clots have been found to be cardioembolic in origin [8][9][10] and less responsive to revascularization attempts.…”
mentioning
confidence: 99%
“…6 Recent studies have shown large-scale heterogeneity in the composition of retrieved clots, in terms of the percentage of fibrin/platelet aggregates (FP), red blood cell (RBC), and white blood cells (WBC). 7 Differences in clot composition have been associated with stroke etiology and MT treatment outcomes. In several studies, FP-rich clots have been found to be cardioembolic in origin [8][9][10] and less responsive to revascularization attempts.…”
mentioning
confidence: 99%
“…Slides were then scanned and quantified using Orbit Image Analysis software. Our quantification method has been published in detail [ 5 ]. In each prepared slide, the percentage of components including RBC and fibrin/platelet was calculated.…”
Section: Methodsmentioning
confidence: 99%
“…Formalin fixed paraffin embedded analogues were sectioned into 3 μm slices and then a representative slide of each analogue was stained with MSB. Histological quantification was performed using Orbit Image Analysis software (https://www.orbit.bio/, licensed under GPLv3) [47]. The percentage of components including RBC and fibrin was determined (Table 1).…”
Section: Methodsmentioning