2014
DOI: 10.1016/j.chroma.2014.07.063
|View full text |Cite
|
Sign up to set email alerts
|

Optimum pH for the determination of bisphenols and their corresponding diglycidyl ethers by gas chromatography–mass spectrometry. Migration kinetics of bisphenol A from polycarbonate glasses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
11
1
2

Year Published

2015
2015
2021
2021

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 19 publications
(14 citation statements)
references
References 25 publications
0
11
1
2
Order By: Relevance
“…This strategy to evaluate the equality of several calibration curves is of great application in chemical analysis, especially to check if matrix effects are present [37], which could 8/34 adversely affect both identification and quantification of analytes if not properly corrected [38]. In GC determinations, a matrix-induced chromatographic response enhancement effect often occurs: in solvent standards without sample matrix present, only the analytes fill the active sites in the system (injector, column, detector), which reduce the percentage of injected molecules eventually detected.…”
Section: Comparison Of Regression Modelsmentioning
confidence: 99%
“…This strategy to evaluate the equality of several calibration curves is of great application in chemical analysis, especially to check if matrix effects are present [37], which could 8/34 adversely affect both identification and quantification of analytes if not properly corrected [38]. In GC determinations, a matrix-induced chromatographic response enhancement effect often occurs: in solvent standards without sample matrix present, only the analytes fill the active sites in the system (injector, column, detector), which reduce the percentage of injected molecules eventually detected.…”
Section: Comparison Of Regression Modelsmentioning
confidence: 99%
“…6 Conventional analytical methods for BPs is usually based on high performance liquid chromatography-tandem mass spectrometry, 7 gas chromatography-mass 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 4 spectrometry. 8,9 These analytical methods require expensive equipment, highly trained technicians and time-consuming sample pretreatment process. Tyrosinase as an 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 5 biosensors, and ZIF-70 showed excellent adsorption capacities toward dehydrogenase immobiliz...…”
mentioning
confidence: 99%
“…Therefore PC material is used to make eyewear [4][5]. Many researchers have been manufactured the PC by using condensation polymerization of bisphenol A and phosgene [6][7][8][9]. Nowadays, it is still worked for evaluation precisely and correctly the physical and chemical properties of bisphenol A and phosgene [10].…”
Section: Introductionmentioning
confidence: 99%