2016
DOI: 10.1016/j.neuroimage.2015.10.048
|View full text |Cite
|
Sign up to set email alerts
|

Optimized parallel transmit and receive radiofrequency coil for ultrahigh-field MRI of monkeys

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
34
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 42 publications
(36 citation statements)
references
References 36 publications
2
34
0
Order By: Relevance
“…1B, D). This geometrical arrangement yields a relatively small noise 682 correlation coefficient (0.084), which is smaller than in previous macaque multi-channel coil designs 683 such as 0.12 in a 24-channel (Gilbert et al, 2016) and 0.22 in a 22-channel (Janssens et al, 2013). Our 684 coil design together with slice and in-plane accelerated imaging allowed up to five-fold and two-by-685 two (MB-by-GRAPPA) accelerations for fMRI and dMRI, respectively.…”
Section: Coil Design 671mentioning
confidence: 85%
“…1B, D). This geometrical arrangement yields a relatively small noise 682 correlation coefficient (0.084), which is smaller than in previous macaque multi-channel coil designs 683 such as 0.12 in a 24-channel (Gilbert et al, 2016) and 0.22 in a 22-channel (Janssens et al, 2013). Our 684 coil design together with slice and in-plane accelerated imaging allowed up to five-fold and two-by-685 two (MB-by-GRAPPA) accelerations for fMRI and dMRI, respectively.…”
Section: Coil Design 671mentioning
confidence: 85%
“…However, 13 C labeled metabolites observed in dynamic 1 H‐ 13 C MRS studies reside in a spectral window of ∼2.6 ppm (1.3–3.9 ppm), hence CSDE is reduced to < 20%. If CSDE is a limitation at higher field strengths, a few modifications to the platform can be exploited: (i) use peak‐ normalB1+ constrained optimal control high bandwidth refocusing pulses ; (ii) replace the volumetric 1 H resonator with a smaller (head‐only) detunable volumetric resonator to achieve higher peak normalB1+; or (iii) at ultra‐high field strengths when the field of view dimensions approach the RF wavelength (∼ λ/2), a detunable transmit array coil can be used in combination with parallel transmit or rf shimming approaches to improve normalB1+ .…”
Section: Discussionmentioning
confidence: 99%
“…However, 13 CSDE is reduced to < 20%. If CSDE is a limitation at higher field strengths, a few modifications to the platform can be exploited: (i) use peak-B þ 1 constrained optimal control high bandwidth refocusing pulses (40,41); (ii) replace the volumetric 1 H resonator with a smaller (head-only) detunable volumetric resonator to achieve higher peak B þ 1 ; or (iii) at ultra-high field strengths when the field of view dimensions approach the RF wavelength ($ l/2), a detunable transmit array coil can be used in combination with parallel transmit or rf shimming approaches to improve B þ 1 (42,43). In addition to the use of RF filters, further attenuation of heteronuclear decoupling signals from coupling to the 1 H channel was achieved with double shielded coax cables, and strategically placing 13 C baluns on all RF carrying cables.…”
Section: Discussionmentioning
confidence: 99%
“…Images were acquired using a 7-T Siemens MAGNETOM head scanner with an in-house designed and manufactured coil optimized for the non-human primate head 46 . Two diffusion weighted scans were acquired for each animal, with each scan having opposite phase encoding in the superior-inferior direction at 1 mm isotropic resolution.…”
Section: Neuroimaging Data Acquisition and Preprocessingmentioning
confidence: 99%