2022
DOI: 10.1016/j.jclepro.2022.132033
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of return vent height for stratified air distribution system with impinging jet supply satisfying threshold of |PMV| < 0.5

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 16 publications
(10 citation statements)
references
References 55 publications
0
10
0
Order By: Relevance
“…Under the extract effect of the thermal plume, the CO 2 can be carried up to the upper space. [45][46][47] Secondly, at the low background air temperature, the exhaled CO 2 with a high temperature more easily rose due to thermal buoyancy. 45 Finally, the exhaust air outlets of MV were located directly above occupants.…”
Section: Inhaled Air Qualitymentioning
confidence: 99%
See 2 more Smart Citations
“…Under the extract effect of the thermal plume, the CO 2 can be carried up to the upper space. [45][46][47] Secondly, at the low background air temperature, the exhaled CO 2 with a high temperature more easily rose due to thermal buoyancy. 45 Finally, the exhaust air outlets of MV were located directly above occupants.…”
Section: Inhaled Air Qualitymentioning
confidence: 99%
“…[45][46][47] Secondly, at the low background air temperature, the exhaled CO 2 with a high temperature more easily rose due to thermal buoyancy. 45 Finally, the exhaust air outlets of MV were located directly above occupants. The CO 2 was just allowed to be carried by the thermal plumes and then exhausted favourably.…”
Section: Inhaled Air Qualitymentioning
confidence: 99%
See 1 more Smart Citation
“…Impinging jet ventilation (IJV) systems would be a promising alternative in cooling densely occupied spaces. Imping jet diffusers supply cold air with high momentum that impinges on the floor and forms a thin cold air layer [ 19 ]. This layer of air can reach far due to high momentum and negative buoyancy.…”
Section: Introductionmentioning
confidence: 99%
“…Firstly, previous research on IJV performances focused primarily on small enclosures or spaces with few rows of occupants. For instance, Qin et al [ 19 , 21 ] and Ye et al [ 22 ] reported CO 2 distribution in a small office with two staff; Wang et al [ 20 ] investigated the contaminant removal for an intensive care unit occupied by four occupants. Secondly, investigations about IJV systems focused mainly on thermal comfort, IAQ, and energy saving, while IJV system's performance on the risk of cross-infection is rarely studied.…”
Section: Introductionmentioning
confidence: 99%